What the LED1 ALT SLOW FLASH / LED2 ALT SLOW FLASH error code actually means

Your furnace tried to light several times but could not maintain a flame, or something caused it to overheat and shut itself off repeatedly. This is a safety lockout that prevents the furnace from continuing to attempt ignition when something is clearly wrong. A technician will need to check the gas supply, the igniter, and the flame sensor to find and fix the underlying problem.

Diagnostic procedure

The full LED1 ALT SLOW FLASH / LED2 ALT SLOW FLASH procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check gas supply, gas valve wiring, ignitor, flame sensor.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock LED1 ALT SLOW FLASH / LED2 ALT SLOW FLASH procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of LED1 ALT SLOW FLASH / LED2 ALT SLOW FLASH

Ranked by how often they cause this code
  1. 1Failed or cracked hot surface ignitor
  2. 2Contaminated or failed flame sensor
  3. 3Gas supply interruption or faulty gas valve
  4. 4Limit switch staying open due to restricted airflow
  5. 5Gas valve wiring fault

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about LED1 ALT SLOW FLASH / LED2 ALT SLOW FLASH

What does LED1 ALT SLOW FLASH / LED2 ALT SLOW FLASH mean on a Lennox furnace?
This alternating slow flash pattern on both diagnostic LEDs indicates a Watchguard lockout condition. The furnace control board triggers this fault when the burners fail to ignite, when a limit switch stays open for more than 3 minutes, or when the flame sensor loses the flame signal 5 times in one heating cycle. The Watchguard function exists to prevent unsafe repeated ignition attempts when a core problem is detected.
Is this error code a safety concern?
Yes, this code reflects a safety lockout that the furnace initiated on its own to prevent a potentially hazardous condition. A furnace that cannot confirm ignition or that is overheating due to restricted airflow should not be forced to run. Do not attempt to bypass the lockout or disable the Watchguard function. Have the system inspected by a qualified technician before returning it to normal operation.
How much does it cost to repair a Lennox furnace showing this error code?
Repair costs vary significantly depending on the root cause. Cleaning a flame sensor is a low-cost service call, typically in the range of $80 to $150 for labor. Replacing a hot surface ignitor generally costs between $150 and $300 including parts and labor. A gas valve replacement or control board issue can bring costs to a range of $350 to $600 or higher. Getting a diagnostic visit to confirm the cause before authorizing repairs is always recommended.
Can I reset the furnace to clear this error code?
Resetting the furnace by cycling power may temporarily clear the lockout and allow the furnace to attempt ignition again. However, if the underlying cause is not corrected, the Watchguard fault will return after the same failure conditions are met. A reset is useful for confirming the fault is active, but it is not a fix and should be followed by a thorough inspection of the gas supply, ignitor, and flame sensor.
How do I fix the LED1 ALT SLOW FLASH / LED2 ALT SLOW FLASH error on my Lennox furnace?
Start by checking that the gas supply valve is fully open and that other gas appliances in the home are working, which rules out a broader supply issue. Next, inspect the air filter and replace it if clogged, then check the flame sensor rod for buildup that can be cleaned with fine steel wool. If the ignitor is cracked or the gas valve wiring is damaged, those components will need repair or replacement. If these steps do not resolve the fault, a technician should perform a complete ignition sequence inspection.