Lennox Furnace Error Code LED1-ALT_FAST_FLASH/LED2-ALT_FAST_FLASH

Improper main ground or line voltage below 75 volts; OR broken ignitor; OR open ignitor circuit.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the LED1-ALT_FAST_FLASH/LED2-ALT_FAST_FLASH error code actually means

Your furnace is detecting either a power supply problem or a broken igniter, which is the part that lights the burner. The furnace has stopped working as a safety precaution because it cannot reliably start a flame. A technician will need to check the electrical connections, incoming voltage, and the igniter itself to determine the exact cause.

Diagnostic procedure

The full LED1-ALT_FAST_FLASH/LED2-ALT_FAST_FLASH procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check that the unit is properly grounded. Check line voltage is above 75V. Check ignitor resistance (10.9-19.7 ohms).
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock LED1-ALT_FAST_FLASH/LED2-ALT_FAST_FLASH procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of LED1-ALT_FAST_FLASH/LED2-ALT_FAST_FLASH

Ranked by how often they cause this code
  1. 1Failed hot surface ignitor
  2. 2Open ignitor circuit wiring
  3. 3Low line voltage below 75 volts
  4. 4Improper or missing main ground
  5. 5Faulty ignitor control relay on the control board

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about LED1-ALT_FAST_FLASH/LED2-ALT_FAST_FLASH

What does LED1-ALT_FAST_FLASH/LED2-ALT_FAST_FLASH mean on a Lennox furnace?
This alternating fast flash pattern on both LEDs indicates that the furnace control board has detected one of three fault conditions: improper main ground, line voltage below 75 volts, or a problem with the ignitor or its circuit. The furnace will not attempt to start a heating cycle until the fault is resolved. Diagnosis involves checking the ground connection, measuring incoming line voltage, and testing ignitor resistance.
Will resetting my Lennox furnace clear this error code?
A power reset may temporarily clear the fault display, but the error will return on the next heating cycle if the underlying problem has not been corrected. Because this fault can involve a failed ignitor or low voltage condition, the furnace may lock out again quickly after a reset. It is best to diagnose and repair the root cause before relying on a reset.
How much does it cost to repair the LED1-ALT_FAST_FLASH/LED2-ALT_FAST_FLASH error on a Lennox furnace?
Repair cost depends on the root cause. A replacement hot surface ignitor typically costs between $20 and $80 for the part, with labor adding $75 to $200 depending on your area and service provider. If the problem is a wiring issue or grounding connection, costs may be lower since no major parts are needed. A control board replacement, if required, can range from $150 to $400 or more for parts alone. A diagnostic service call is usually the first step to confirm what component is at fault.
How do I fix the LED1-ALT_FAST_FLASH/LED2-ALT_FAST_FLASH error on my Lennox furnace?
Start by verifying the furnace is properly grounded and that line voltage at the unit measures above 75 volts. Next, disconnect the ignitor and measure its resistance with a multimeter; the correct cold resistance range is 10.9 to 19.7 ohms, and a reading outside this range or an open circuit means the ignitor needs replacement. Also inspect the ignitor wiring harness for loose or damaged connectors. If voltage and grounding are correct and the ignitor tests good, the control board relay may need further evaluation by a qualified technician.
Is it safe to run my furnace when it shows this error?
The furnace will generally not operate in a heating cycle while this fault is active, which is a built-in safety function. You should not attempt to bypass the control board or force the furnace to run while this fault is present. Low voltage or grounding issues can pose electrical hazards, and a failed ignitor left unaddressed can lead to failed ignition attempts that allow gas to accumulate briefly. Have the system inspected promptly.