What the LED1-ALT_SLOW_FLASH/LED2-ALT_SLOW_FLASH error code actually means

Your Lennox furnace tried to light the burners several times but could not get them to ignite, so it shut itself down as a safety measure. This is usually related to a gas supply problem or a worn igniter. A technician will need to check the gas pressure and ignition components to find the exact cause.

Diagnostic procedure

The full LED1-ALT_SLOW_FLASH/LED2-ALT_SLOW_FLASH procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check that gas is being supplied to the unit. Check line pressure at the gas valve.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock LED1-ALT_SLOW_FLASH/LED2-ALT_SLOW_FLASH procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of LED1-ALT_SLOW_FLASH/LED2-ALT_SLOW_FLASH

Ranked by how often they cause this code
  1. 1Insufficient or No Gas Supply
  2. 2Failed or Weak Hot Surface Igniter
  3. 3Faulty or Stuck Gas Valve
  4. 4Dirty or Corroded Flame Sensor
  5. 5Control Board Fault

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about LED1-ALT_SLOW_FLASH/LED2-ALT_SLOW_FLASH

What does LED1-ALT_SLOW_FLASH/LED2-ALT_SLOW_FLASH mean on a Lennox furnace?
This code indicates a Watchguard fault, meaning the furnace control board detected that the burners failed to ignite after multiple attempts. The alternating slow flash pattern on both LED indicators is the board's way of signaling this specific lockout condition. The furnace will not attempt to heat again until the fault is addressed and the system is reset.
How do I fix the LED1-ALT_SLOW_FLASH/LED2-ALT_SLOW_FLASH error on my Lennox furnace?
Start by confirming that gas is being supplied to the furnace: check that the manual shutoff valve is fully open and verify line pressure at the gas valve inlet. If gas supply is confirmed, the next steps involve inspecting the igniter, testing the gas valve for proper operation, and cleaning or testing the flame sensor. A qualified technician should perform voltage and resistance testing on these components to identify the specific failure.
How much does it cost to repair a Lennox furnace with this ignition fault?
Repair costs vary depending on which component has failed. Flame sensor cleaning or igniter replacement is typically in the range of $100 to $300 including labor. Gas valve replacement tends to cost more, often in the range of $250 to $600 depending on the part and labor rates in your area. Control board replacement is generally the most expensive repair, often ranging from $400 to $700 or more.
Will resetting the furnace clear this error code?
Resetting the furnace by cycling power may clear the lockout temporarily and allow the furnace to attempt ignition again. However, if the underlying cause is not corrected, the burners will fail to ignite again and the Watchguard fault will return. A reset is useful for confirming the fault is active, but it is not a fix on its own.
Is it safe to keep running a furnace showing this error code?
The furnace will not continue operating while this Watchguard lockout is active, so there is no ongoing risk from the furnace itself continuing to run. However, you should not repeatedly reset and attempt to force ignition without diagnosing the cause, as repeated failed ignition attempts can allow unburned gas to accumulate. If you smell gas at any point, leave the home and contact your gas utility immediately.