Lennox Furnace Error Code LED#1 Fast Flash / LED#2 Slow Flash

Main power polarity reversed

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the LED#1 Fast Flash / LED#2 Slow Flash error code actually means

Your furnace's power wiring was connected backwards, with the hot wire and neutral wire swapped at the wrong terminals. The furnace detected this and shut itself down as a safety precaution. A technician or qualified electrician needs to swap those two wires to the correct positions before the furnace will run again.

Diagnostic procedure

The full LED#1 Fast Flash / LED#2 Slow Flash procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Switch line and neutral at 120V field connection.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock LED#1 Fast Flash / LED#2 Slow Flash procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of LED#1 Fast Flash / LED#2 Slow Flash

Ranked by how often they cause this code
  1. 1Incorrect installation wiring
  2. 2Reversed wiring after service or repair
  3. 3Reversed polarity at the disconnect or outlet
  4. 4Improperly labeled or color-coded field wiring

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about LED#1 Fast Flash / LED#2 Slow Flash

What does LED#1 Fast Flash / LED#2 Slow Flash mean on a Lennox furnace?
This flash code indicates that the 120V main power supply wiring has reversed polarity, meaning the line (hot) and neutral conductors are connected to the wrong terminals at the furnace's field wiring connection. The control board detects this condition and locks out furnace operation as a safety measure. The fix requires swapping the line and neutral wires to their correct terminals after turning off power at the breaker.
Is a reversed polarity error on a Lennox furnace dangerous?
Yes, reversed polarity is a genuine electrical safety concern and is one reason the furnace locks out rather than continuing to operate. Running equipment with reversed polarity can create shock hazards and may damage the control board or other components over time. The furnace's lockout behavior is a protective response, and the wiring should be corrected promptly by a qualified technician.
How much does it cost to fix a reversed polarity error on a Lennox furnace?
Because the repair involves only a wiring correction and no replacement parts, the cost is primarily labor. A service call from an HVAC technician to diagnose and correct this wiring issue typically ranges from $75 to $200 depending on your location and the technician's rates. If the polarity reversal originates upstream at a disconnect or electrical panel, an electrician may also need to be involved, which could add to the total cost.
How do I fix the LED#1 Fast Flash / LED#2 Slow Flash error on my Lennox furnace?
Turn off power to the furnace at the circuit breaker before doing anything else. Locate the 120V field wiring connection inside the furnace cabinet and identify the line and neutral conductors. Switch their positions so each wire is connected to its correct terminal, then restore power and check whether the error clears. If you are not comfortable working with electrical wiring, a qualified HVAC technician or electrician should perform this correction.
Will resetting the furnace clear the LED#1 Fast Flash / LED#2 Slow Flash code?
No, resetting the furnace will not permanently clear this error because the control board will re-detect the reversed polarity condition every time power is applied. The underlying wiring fault must be corrected first. Only after the line and neutral wires are connected to their proper terminals will the error code stop appearing.