Lennox Furnace Error Code LED1-FAST_FLASH/LED2-SLOW_FLASH

Main power polarity reversed

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the LED1-FAST_FLASH/LED2-SLOW_FLASH error code actually means

Your furnace is detecting that its electrical power wires are connected backwards. This is a wiring problem, not a broken part, and it means the hot and neutral wires were swapped at some point during installation or a recent repair. An electrician or HVAC technician can correct this quickly by swapping two wires at the furnace electrical connection.

Diagnostic procedure

The full LED1-FAST_FLASH/LED2-SLOW_FLASH procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check the 120V has line and neutral correctly input into control. Reverse the line and neutral at the 120V field connection.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock LED1-FAST_FLASH/LED2-SLOW_FLASH procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of LED1-FAST_FLASH/LED2-SLOW_FLASH

Ranked by how often they cause this code
  1. 1Incorrect initial installation wiring
  2. 2Wiring reversed during a service call
  3. 3Reversed polarity at the circuit breaker or junction box
  4. 4Mis-labeled or improperly color-coded field wiring

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about LED1-FAST_FLASH/LED2-SLOW_FLASH

What does LED1-FAST_FLASH/LED2-SLOW_FLASH mean on a Lennox furnace?
This blink code means the furnace control board has detected that the 120V main power supply has reversed polarity, with the line and neutral conductors connected to the wrong terminals. The control board monitors incoming power polarity and locks out furnace operation when a reversal is detected. The fix requires swapping the line and neutral wires at the 120V field connection point. No parts replacement is needed in most cases.
Is reversed polarity on a Lennox furnace dangerous?
Yes, reversed polarity is a legitimate electrical safety concern. When line and neutral are swapped, components that are intended to be de-energized when switched off may still carry voltage, creating a shock hazard and potential for equipment damage. The Lennox control board correctly identifies and locks out the furnace under this condition to prevent unsafe operation. The wiring should be corrected before restoring furnace operation.
How much does it cost to fix a reversed polarity fault on a Lennox furnace?
Because this is a wiring correction rather than a parts replacement, the cost is typically limited to a service call and labor fee, generally in the range of $75 to $200 depending on your location and the technician's rates. If the reversed polarity exists upstream at a junction box or breaker panel and requires an electrician, costs could be somewhat higher. No replacement parts are needed for a straightforward polarity reversal at the furnace field connection.
Can I fix the LED1-FAST_FLASH/LED2-SLOW_FLASH polarity error myself?
Correcting reversed polarity involves working directly with 120V AC wiring, which presents a shock hazard if not handled properly. A qualified HVAC technician or licensed electrician should perform this repair. The actual correction is straightforward: the line and neutral conductors are physically swapped at the 120V field connection on the control board, but the power supply to the furnace must be shut off at the breaker before touching any wiring.
Will resetting the furnace clear the LED1-FAST_FLASH/LED2-SLOW_FLASH error?
No, resetting the furnace will not clear this fault. The control board detects reversed polarity from the incoming power supply on a continuous basis, so the fault code will return immediately after any reset attempt as long as the line and neutral conductors remain swapped. The underlying wiring must be corrected first, after which the fault should clear on its own without requiring a manual reset.