Lennox Furnace Error Code LED1-OFF/LED2-SLOW_FLASH

Pressure switch open or has opened 5 times during a single call for heat; OR blocked inlet/exhaust vent; OR condensate line blocked; OR pressure…

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the LED1-OFF/LED2-SLOW_FLASH error code actually means

Your Lennox furnace has detected a problem with the airflow safety switch that checks whether air is moving properly before allowing the burners to light. This can happen because the exhaust or intake pipes are blocked, the drain line is clogged, or the switch itself has failed. The furnace is shutting down to prevent unsafe operation until the problem is resolved.

Diagnostic procedure

The full LED1-OFF/LED2-SLOW_FLASH procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check pressure switch is open without combustion air blower operating; check for restricted inlet/exhaust vent; check condensate line.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock LED1-OFF/LED2-SLOW_FLASH procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of LED1-OFF/LED2-SLOW_FLASH

Ranked by how often they cause this code
  1. 1Blocked inlet or exhaust vent
  2. 2Clogged condensate drain line
  3. 3Failed or out-of-range pressure switch
  4. 4Pressure switch hose cracked or disconnected
  5. 5Weak or failing inducer motor

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about LED1-OFF/LED2-SLOW_FLASH

What does LED1-OFF/LED2-SLOW_FLASH mean on a Lennox furnace?
This code indicates a pressure switch fault. The pressure switch monitors whether the combustion air blower is generating adequate airflow before ignition is allowed. The fault can appear because the switch failed to close during startup, opened during operation, opened five or more times in one heating cycle, or was already closed before the inducer turned on. Common triggers include blocked vents, a clogged condensate line, or a faulty pressure switch.
Is it safe to run my furnace with this error code showing?
No. This fault code causes the furnace to shut down the ignition sequence intentionally, meaning it will not produce heat while the fault is active. Attempting to repeatedly reset the furnace without identifying the root cause does not make it safe to operate. The pressure switch system exists to prevent combustion without proper airflow, and bypassing or ignoring this fault creates a risk of incomplete combustion or carbon monoxide production.
How much does it cost to repair this pressure switch fault on a Lennox furnace?
Repair costs vary depending on the cause. Clearing a blocked vent or condensate line may cost relatively little if no parts are needed, typically in the range of a standard diagnostic service fee. Replacing a pressure switch generally falls in the range of $100 to $300 including parts and labor. Inducer motor replacement is more involved and can range from $300 to $700 or more depending on the specific model and local labor rates.
Can I fix this error myself, or do I need a technician?
Some causes can be addressed by a homeowner, including clearing visible blockages at exterior vent terminations and checking the condensate drain line for obvious clogs. However, testing the pressure switch with a manometer, inspecting internal hoses, and evaluating the inducer motor require tools and skills typically held by a trained technician. If basic visual checks do not reveal the problem, professional service is recommended.
Will resetting the furnace clear this error code?
A reset may temporarily clear the fault and allow the furnace to attempt another startup cycle, but if the underlying cause is not corrected, the error will return. Because this fault also triggers after the pressure switch opens five times in a single call for heat, repeated resets without a fix will cause the fault to reappear quickly. Identifying and correcting the root cause is necessary before the furnace will operate reliably.