mypros+
Error code reference

Lennox Furnace Error Code LED#1 ON / LED#2 Slow Flash

Rollout switch open, or 12-pin connector improperly attached.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the LED#1 ON / LED#2 Slow Flash error code actually means

Your Lennox furnace has detected a problem with a safety switch that monitors whether flames are staying where they should be inside the burner area. The furnace shut itself down to protect your home from a potentially dangerous situation. A technician needs to find out why this safety switch tripped before the furnace is restarted.

Diagnostic procedure

The full LED#1 ON / LED#2 Slow Flash procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Manually reset the rollout switch by pushing the top button; determine cause of rollout switch activation.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock LED#1 ON / LED#2 Slow Flash procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of LED#1 ON / LED#2 Slow Flash

Ranked by how often they cause this code
  1. 1Rollout switch tripped due to restricted airflow
  2. 2Blocked flue or vent pathway
  3. 3Improperly seated 12-pin connector
  4. 4Failed or nuisance-tripping rollout switch
  5. 5Cracked heat exchanger

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about LED#1 ON / LED#2 Slow Flash

What does LED#1 ON / LED#2 Slow Flash mean on a Lennox furnace?
This code indicates that the rollout switch has opened, or that the 12-pin connector in the burner section is not properly attached. The rollout switch is a thermal safety device that trips when flames extend outside the normal combustion zone. The furnace shuts down to prevent a potentially hazardous condition until the cause is identified and corrected.
Is it safe to run my Lennox furnace when this error code appears?
No, you should not attempt to run the furnace while this code is active without first determining why the rollout switch opened. Flame rollout is a serious safety hazard that can result in fire or carbon monoxide production. The furnace should remain off until a qualified technician has inspected the unit and confirmed the cause has been corrected.
How much does it cost to repair a Lennox furnace showing this error?
Repair costs vary widely depending on the cause. Simple fixes like replacing an air filter or reseating a connector cost little to nothing beyond a service call fee, which typically ranges from $75 to $150. Replacing a rollout switch generally runs $100 to $250 in parts and labor. If a cracked heat exchanger is found, repair or replacement costs can range from $500 to over $2,000 depending on furnace age and part availability.
Can I reset the rollout switch myself to fix this error?
You can manually reset the rollout switch by pressing the button on top of the switch, but resetting it without finding the root cause is not a long-term fix. If the condition that caused the switch to trip is still present, it will trip again. A thorough inspection of airflow, venting, and the burner area should be completed before or immediately after the reset.
Will resetting the rollout switch clear this error code permanently?
Resetting the switch will allow the furnace to attempt operation again, but the code will return if the underlying problem is not fixed. If the root cause is something like a dirty filter or a disconnected 12-pin connector, correcting that issue along with the reset should clear the fault. If the cause is a blocked flue, failed switch, or cracked heat exchanger, those repairs are required before the code stays cleared.