Lennox Furnace Error Code LED1-SLOW_FLASH/LED2-OFF

Flame sensed without gas valve energized.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the LED1-SLOW_FLASH/LED2-OFF error code actually means

Your furnace is detecting what it thinks is a flame even though it did not turn on the gas burner, which is a safety concern that caused it to shut down. This usually means a faulty sensor, a wiring problem, or in rare cases, a gas valve that is not closing properly. The furnace will not run normally until this issue is diagnosed and resolved.

Diagnostic procedure

The full LED1-SLOW_FLASH/LED2-OFF procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
Confirm the fault
Power cycle the unit: switch off the breaker for 60 seconds, then restore power. If the code returns, the fault is persistent and the procedure below isolates the cause.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock LED1-SLOW_FLASH/LED2-OFF procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of LED1-SLOW_FLASH/LED2-OFF

Ranked by how often they cause this code
  1. 1Failed or shorted flame sensor
  2. 2Faulty control board flame sensor input circuit
  3. 3Shorted or damaged flame sensor wiring
  4. 4Contaminated flame sensor rod
  5. 5Leaking or sticking gas valve

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about LED1-SLOW_FLASH/LED2-OFF

What does LED1-SLOW_FLASH/LED2-OFF mean on a Lennox furnace?
This code means the furnace control board has detected a flame sensor signal while the gas valve has not been commanded to open. The furnace shuts down as a safety precaution because a flame should only be present when the board has specifically energized the gas valve. The fault points to a problem in the flame sensing circuit, the control board, the wiring, or in rare cases, the gas valve itself.
Will resetting the furnace clear this error code?
A power reset may temporarily clear the lockout and allow the furnace to attempt another cycle, but if the underlying fault is still present, the code will return quickly. Resetting without diagnosing and repairing the root cause is not a long-term solution and could mask a safety-relevant problem. Persistent or recurring appearances of this code require component-level diagnosis.
How much does it cost to repair a Lennox furnace showing this fault code?
Repair costs depend on which component is at fault. Flame sensor replacement is typically the least expensive repair, often in the range of $75 to $200 including labor. Control board replacement is more costly, generally ranging from $300 to $600 or more depending on the board. Gas valve replacement can range from $250 to $600 or higher. A diagnostic service call to identify the root cause usually runs $80 to $150 before parts.
Is it safe to run my Lennox furnace when this error is displayed?
No, you should not attempt to bypass this fault or force the furnace to run. This code indicates a disagreement between what the control board commanded and what the sensors are detecting, which could point to an uncontrolled combustion condition. If a leaking gas valve is the cause, continued operation poses a fire or carbon monoxide risk. Have the system inspected by a qualified technician before restoring operation.
How do I fix the LED1-SLOW_FLASH/LED2-OFF fault on a Lennox furnace?
Start by inspecting and cleaning the flame sensor rod, then check the sensor wiring for shorts or damage. Test the flame sensor circuit for leakage current with the gas valve de-energized. If the sensor and wiring are intact, the control board or the gas valve may need to be replaced. A qualified technician with a multimeter and combustion analysis tools can isolate the defective component.