Error code reference

Lennox Furnace Error Code LED1-SLOW_FLASH/LED2-ON

Primary or secondary limit open. Units with board 63K8901 or 24L85

Primary or secondary limit open. Units with board 63K8901 or 24L85: Limit must close within 5 trials for ignition or board goes into one hour limit Watchguard. Units with board 56L83 or 97L48: Limit must close within 3 minutes or board goes into one hour limit Watchguard.

First step from the service manual

Check continuity across limit switch(es). Switches reset automatically upon cool down. Check for restrictions on blower inlet air (including filter) and outlet air.

The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.