What the 103 error code actually means

This error means one of the compressors in your outdoor air conditioning unit got too hot and shut itself off to avoid damage. The system is protecting itself from a condition that could permanently harm expensive internal parts. A technician needs to inspect the unit to find out why the compressor overheated before it can safely restart.

Diagnostic procedure

The full 103 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check open status of the service valve.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 103 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 103

Ranked by how often they cause this code
  1. 1Closed or partially closed service valve
  2. 2Low refrigerant charge
  3. 3Blocked or fouled outdoor heat exchanger coil
  4. 4Faulty or stuck expansion valve
  5. 5Defective discharge temperature sensor

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 103

What does 103 mean on a LG air_conditioner?
Error code 103 indicates that the discharge temperature of the No. 2 constant speed compressor in the Sub2 outdoor unit has exceeded its safe operating limit in a three-unit system. The compressor has been shut down automatically to prevent internal damage. A technician should check the service valve status on that outdoor unit as the first diagnostic step before investigating refrigerant charge and heat exchanger condition.
Is it safe to keep running my LG air conditioner when error code 103 appears?
No. The system has already shut down the affected compressor as a protective measure. Attempting to override or restart the unit repeatedly without resolving the root cause can cause permanent damage to the compressor internals, including valve failure and motor winding burnout. Leave the system off and contact a qualified technician for diagnosis.
How much does it cost to repair a LG air conditioner showing error code 103?
Repair cost depends heavily on the root cause. If the fix is simply opening a service valve, the cost is primarily a service call fee, typically in the range of $75 to $150. Refrigerant leak repair and recharge can range from $200 to $600 or more depending on the refrigerant type and leak location. Compressor replacement on a commercial multi-zone system is a major repair that can range from $800 to $2,500 or higher including labor and parts.
Can I fix error code 103 on my LG air conditioner myself?
The first step, checking whether the service valve on the outdoor unit is fully open, can be done without special tools and may resolve the fault if the valve was inadvertently left closed after prior service. However, if the valve is open, diagnosing the underlying cause requires refrigerant manifold gauges, sensor resistance testing, and potentially handling refrigerant, all of which require certified HVAC technician qualifications. Attempting refrigerant work without proper certification is illegal in most jurisdictions.
Will resetting my LG air conditioner clear error code 103?
A power reset may temporarily clear the fault and allow the compressor to restart, but if the underlying condition causing high discharge temperature has not been corrected, the error will return and the compressor will shut down again. Repeated fault cycles without repair can progressively damage the compressor. A reset should only be performed after the root cause has been identified and corrected.