What the 104 error code actually means

Your LG air conditioning system has multiple outdoor units that work together, and right now the main outdoor unit has lost contact with one of its partner units. The system cannot confirm that the secondary outdoor unit is operating correctly, so it has flagged this error to prevent potential damage. A technician will need to inspect the wiring and control boards connecting the two units.

Diagnostic procedure

The full 104 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
During power input reset, check the third value in sequence on main PCB 7-segment for outdoor connecting counts.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 104 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 104

Ranked by how often they cause this code
  1. 1Damaged or disconnected communication wiring between outdoor units
  2. 2Incorrect outdoor connecting count after power reset
  3. 3Faulty Sub1 outdoor unit PCB
  4. 4Faulty main outdoor unit PCB
  5. 5Power supply issue to Sub1 outdoor unit

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 104

What does 104 mean on a LG air_conditioner?
Error code 104 on an LG air conditioner indicates a communication failure between the main outdoor unit PCB and the Sub1 outdoor unit. The main PCB is not receiving the expected data signal from Sub1. This error is specific to multi-outdoor-unit system configurations and typically requires inspection of the inter-unit communication wiring and control boards.
Will resetting my LG air conditioner clear error code 104?
A power reset may temporarily clear the fault display, but if the underlying communication problem persists, the error will return. The reset is actually a useful diagnostic step: monitoring the third value in the 7-segment sequence during startup will show whether the main PCB is detecting Sub1 after the reset. A persistent low connecting count confirms the fault has not resolved.
How much does it cost to repair error code 104 on an LG air conditioner?
Repair costs vary depending on the cause. If the fix involves reseating loose communication cable terminals, the cost is primarily a service call fee, typically in the range of $75 to $150. If a control board needs replacement, parts and labor combined can range from $300 to $700 or more depending on the specific PCB required and local labor rates. Getting a diagnosis before committing to parts replacement is advisable.
Can I fix error code 104 on my LG air conditioner myself?
Some basic checks are accessible to a knowledgeable DIYer, such as visually inspecting the communication cables between outdoor units for obvious damage or loose terminal connections. However, diagnosing the 7-segment display during a power reset sequence and testing PCB communication circuits requires familiarity with the system's architecture and safe electrical practices. PCB replacement should be handled by a qualified technician.
Is it safe to run my LG air conditioner with error code 104 active?
Operating the system with error code 104 active is not recommended. The main outdoor unit cannot confirm the status of the Sub1 unit, which means the system is running without full visibility into compressor and load conditions across the outdoor units. Continuing to run the system in this state risks compressor damage or uncontrolled operating conditions. The system should be inspected before resuming normal use.