mypros+
Error code reference

LG Air Conditioner Error Code 107

Low voltage of main outdoor fan motor driver

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the 107 error code actually means

Your LG air conditioner's outdoor unit is detecting that the fan motor's power supply circuit is not charging up properly, which prevents the fan from running safely. The system shut itself down to avoid further damage. A technician will need to inspect the internal wiring and the fan motor control board in the outdoor unit to resolve this.

Diagnostic procedure

The full 107 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check DC LINK cable connection; replace inverter fan PCB if cable is normal.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 107 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 107

Ranked by how often they cause this code
  1. 1Loose or faulty DC link cable connection
  2. 2Failed inverter fan PCB
  3. 3Damaged or open-circuit DC link cable
  4. 4Low or unstable incoming power supply voltage
  5. 5Corroded or oxidized connector terminals

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 107

What does 107 mean on a LG air_conditioner?
Error code 107 on an LG air conditioner indicates a low voltage condition in the main outdoor fan motor driver, caused by a DC voltage charging failure in the inverter fan motor drive circuit. The outdoor unit detects that the DC link voltage is not reaching the required level during startup. The system shuts down to protect the fan motor and drive electronics from damage. A technician should inspect the DC link cable connection and the inverter fan PCB.
Is it safe to keep running my LG AC with error code 107 active?
No, you should not continue operating the unit while error code 107 is active. The outdoor fan is not running correctly, which means the refrigerant circuit and compressor are not being properly cooled. Continued operation under this condition can cause compressor overheating and potentially lead to more extensive and costly damage. Power down the outdoor unit until the fault is diagnosed and repaired.
How much does it cost to repair LG error code 107?
Repair costs depend on the root cause. If the issue is simply a loose or corroded DC link cable connection, the cost may be limited to a diagnostic service call fee, typically in the range of $75 to $150. If the inverter fan PCB requires replacement, parts and labor combined can range from $300 to $700 or more depending on the specific unit model and local labor rates. Getting a diagnosis before authorizing repairs is the best way to understand the actual cost.
Can I fix LG error code 107 myself?
The first diagnostic step is checking the DC link cable connection inside the outdoor unit, which involves working near high-voltage components. This work is not recommended for homeowners without electrical training, as the DC link capacitors can hold dangerous voltage even after power is disconnected. A qualified HVAC technician should perform the inspection and any required repairs. If the cable connection is normal, the inverter fan PCB will need to be replaced.
Will resetting my LG air conditioner clear error code 107?
A power reset may temporarily clear the error display, but if the underlying cause is not repaired, the fault will return when the unit attempts to start the outdoor fan again. A loose DC link cable may occasionally make intermittent contact, causing the code to appear and disappear, but this does not indicate a resolved problem. Persistent recurrence of error 107 after resets confirms that a physical inspection is needed.