mypros+
Error code reference

LG Air Conditioner Error Code 110

Wrong connection of 3 phase power cable of sub1 outdoor unit (reverse phase or phase omission).

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the 110 error code actually means

This error means your outdoor air conditioning unit is detecting a problem with how the electrical power is connected to it. Either the three power wires are hooked up in the wrong order, or one of the wires is not delivering power at all. This is an installation or electrical supply issue that needs to be checked by a qualified technician before the unit can run safely.

Diagnostic procedure

The full 110 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check connection and phase order of power cables.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 110 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 110

Ranked by how often they cause this code
  1. 1Incorrect phase wiring order at the terminal block
  2. 2Single-phase omission due to a blown fuse or tripped breaker pole
  3. 3Loose or disconnected power cable terminal
  4. 4Utility supply phase loss
  5. 5Damaged or open power cable conductor

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 110

What does 110 mean on a LG air_conditioner?
Error code 110 on an LG air conditioner indicates a three-phase power wiring fault on the Sub1 outdoor unit. The system has detected either a reversed phase sequence or a missing phase. This prevents the outdoor unit from operating safely and requires inspection of the power cable connections and the incoming supply voltage before the unit can restart.
Is error code 110 on an LG air conditioner dangerous?
Yes, running a three-phase compressor with reversed phase or a missing phase can cause serious mechanical and electrical damage. A reversed phase causes rotating components to spin in the wrong direction, which can destroy compressor internals very quickly. The unit's protection circuit triggers error 110 to prevent this damage, so the system should not be forced to operate until the wiring fault is corrected.
How much does it cost to repair error code 110 on an LG air conditioner?
If the fix is simply correcting the phase wiring order at the terminal block, the cost is typically just a service call fee, which can range from $75 to $200 depending on your area. If a blown fuse or failed breaker pole is involved, parts and labor could add $50 to $150 or more. If the incoming power cable itself is damaged and needs replacement, costs could range from $200 to $600 or higher depending on cable length and labor involved.
How do I fix error code 110 on my LG air conditioner?
Start by shutting off power to the outdoor unit at the disconnect switch and verifying the phase order of the three power cables at the Sub1 outdoor unit terminal block against the wiring diagram. Use a phase sequence tester or multimeter to confirm all three phases are present and in the correct L1, L2, L3 order. If a phase is missing, trace the fault back through the disconnect, fuses, and breaker panel. Correcting the wiring order or restoring the missing phase should clear the fault after power is restored.
Will resetting the LG air conditioner clear error code 110?
A simple reset will not permanently clear error code 110 if the underlying wiring fault still exists. The phase detection circuit will re-detect the reverse phase or missing phase condition as soon as the unit attempts to start and the error will return. The fault must be corrected at the power supply or terminal block before a reset will be effective.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started