What the 115 error code actually means

Your LG air conditioner has detected a problem with a temperature sensor located on the outdoor unit that monitors the refrigerant as it flows through a cooling stage of the system. The sensor is either not sending any signal or is sending a signal that is clearly wrong, so the unit has stopped operating normally to protect itself. A technician will need to check the wiring and the sensor itself to determine whether the connection has come loose or the sensor needs to be replaced.

Diagnostic procedure

The full 115 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check temperature sensor connector connections; check sensor resistance value.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 115 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 115

Ranked by how often they cause this code
  1. 1Loose or disconnected sensor connector
  2. 2Failed sensor thermistor
  3. 3Damaged sensor wiring harness
  4. 4Corroded or moisture-contaminated connector
  5. 5Faulty outdoor unit control board

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 115

What does 115 mean on a LG air conditioner?
Error code 115 on an LG air conditioner indicates that the outdoor unit's subcooling outlet temperature sensor has been detected as either open or shorted. This means the control board is receiving no signal or an out-of-range signal from the sensor that monitors refrigerant temperature at the subcooling circuit outlet. The unit will limit or stop operation until the fault is resolved. Diagnosis starts with inspecting the sensor's wiring connector for secure attachment and physical damage.
Is it safe to keep running my LG air conditioner while error code 115 is active?
It is not advisable to continue operating the system while error code 115 is active. The subcooling outlet temperature sensor provides data the control system uses to manage refrigerant flow and protect the compressor. Running the unit without a valid sensor reading can lead to inefficient operation or compressor damage over time. Address the fault before resuming normal use.
Will resetting my LG air conditioner clear error code 115?
A power reset may temporarily clear the error code display, but the code will return if the underlying sensor fault still exists. The control board will detect the open or shorted sensor signal again as soon as it runs its diagnostic checks. A reset is useful for confirming whether a fault is persistent, but it is not a repair. The sensor, wiring, and connector must be inspected and corrected to permanently resolve the error.
Can I fix error code 115 on my LG air conditioner myself?
A homeowner comfortable with basic electrical inspection can check whether the sensor connector has come loose, as reconnecting it may clear the fault. However, testing sensor resistance, tracing wiring faults, and replacing the sensor or control board involves working inside the outdoor unit and requires a multimeter and basic electrical knowledge. Any work involving the refrigerant circuit should be left to a licensed HVAC technician.
How much does it cost to repair error code 115 on a LG air conditioner?
If the fix is simply reseating a loose connector, there may be no parts cost, only a diagnostic service call fee which typically ranges from $75 to $150. Replacing the subcooling outlet temperature sensor itself usually costs between $50 and $150 for the part, plus labor. If the outdoor unit control board has failed, parts and labor can range from $300 to $700 or more depending on the unit model and market rates.