mypros+
Error code reference

LG Air Conditioner Error Code 135

Temperature sensor of front-side heat exchanger (A) of sub2 outdoor unit is open or short.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the 135 error code actually means

Your LG air conditioner's outdoor unit has a small temperature sensor that monitors part of its internal coil, and this sensor is either disconnected or has failed. The system detected a problem with the sensor's electrical signal and shut down to protect the unit. A technician will need to inspect the sensor and its wiring to restore normal operation.

Diagnostic procedure

The full 135 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Refer to CH45 procedure.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 135 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 135

Ranked by how often they cause this code
  1. 1Failed thermistor sensor
  2. 2Loose or disconnected wiring connector
  3. 3Damaged wiring harness
  4. 4Corrosion at connector terminals
  5. 5Faulty outdoor unit control board

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 135

What does 135 mean on a LG air_conditioner?
Error code 135 indicates that the temperature sensor monitoring the front-side heat exchanger (A) on the sub2 outdoor unit has an open or short circuit condition. The control board cannot get a valid reading from this thermistor and shuts down operation to protect the system. Diagnosis follows the CH45 procedure, which involves inspecting the sensor, wiring, and control board connections.
Will resetting my LG air conditioner clear error code 135?
A power reset may temporarily clear the code and allow the unit to restart, but if the sensor or wiring fault is still present, the error will return quickly. The underlying cause must be repaired before the system will operate normally without retriggering the fault.
How much does it cost to repair error code 135 on a LG air conditioner?
Repair costs vary depending on what component has failed. If only the sensor thermistor needs replacement, parts and labor costs typically range from around $75 to $200. If the wiring harness or the outdoor unit control board requires replacement, costs can range from $150 to $600 or more depending on the unit model and local labor rates.
Can I fix error code 135 on my LG air conditioner myself?
A knowledgeable DIYer can check for obvious issues such as a loose or disconnected sensor connector at the outdoor unit control board. However, properly diagnosing an open or shorted thermistor requires a multimeter and knowledge of expected resistance values at given temperatures. Replacing components inside the outdoor unit is best handled by a certified HVAC technician.
Is it safe to keep running my LG air conditioner with error code 135?
Error code 135 typically causes the system to stop operating as a protective measure. Attempting to force operation without a functioning heat exchanger temperature sensor removes an important safeguard and could lead to coil damage or compressor issues. The fault should be repaired before resuming normal use.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass