LG Air Conditioner Error Code 141

Wrong connection of 3 phase power cable of sub2 outdoor unit (reverse phase or phase omission).

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the 141 error code actually means

This error means the outdoor unit is detecting that its power supply wires are either connected in the wrong order or one of the wires has come loose or is missing. This is a safety protection to prevent the compressor from spinning the wrong direction, which would damage it. A licensed electrician or HVAC technician should check and correct the wiring before the unit is restarted.

Diagnostic procedure

The full 141 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check connection and phase order of power cables.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 141 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 141

Ranked by how often they cause this code
  1. 1Reversed phase wiring at terminal block
  2. 2Loose or disconnected phase conductor
  3. 3Incorrect phase sequence from upstream supply
  4. 4Damaged or deteriorated wiring
  5. 5Faulty phase detection circuit on control board

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 141

What does 141 mean on a LG air_conditioner?
Error code 141 indicates that the Sub2 outdoor unit has detected a reverse phase connection or a disconnection in its R, S, T three-phase power supply. The system locks out to prevent the compressor from running in the wrong direction, which would cause mechanical damage. Correcting the wiring sequence or reconnecting the loose conductor will resolve the fault.
Is it safe to keep running the air conditioner with error code 141 active?
No. The system is designed to prevent operation when this fault is active, and attempting to force the unit on with incorrect phase wiring would cause the compressor to rotate in reverse, leading to serious mechanical damage and potential compressor failure. Leave the unit off until the wiring issue is diagnosed and corrected.
Will resetting the LG air conditioner clear error code 141?
A power reset will temporarily clear the fault display, but the error will return immediately on startup if the underlying wiring problem has not been corrected. The phase sequence detection runs each time the unit attempts to start, so the code will reappear until the R, S, T connections are properly verified and corrected at the Sub2 outdoor unit.
Can I fix error code 141 myself?
Diagnosing and correcting three-phase power wiring requires working inside electrical panels and terminal blocks at line voltage levels, which is hazardous without proper training and equipment. A licensed electrician or certified HVAC technician should perform this repair. If you are technically experienced and the issue is simply a transposed wire at the outdoor unit terminal block, re-landing the conductors in the correct R, S, T order can resolve it, but always shut off power at the disconnect before touching any wiring.
How much does it cost to repair error code 141 on an LG air conditioner?
If the fix is simply re-terminating correctly ordered wires at the outdoor unit terminal block, labor costs from a technician could range from roughly $75 to $200 depending on your area. If upstream wiring needs to be replaced or a control board has failed, costs can range from $200 to $800 or more including parts and labor. Getting a diagnosis from a qualified technician will clarify which scenario applies.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass