LG Air Conditioner Error Code 145

High pressure rise of Sub2 outdoor unit

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the 145 error code actually means

Your LG air conditioning system detected dangerously high pressure in one of the outdoor units and shut down its compressor to prevent damage. This is a safety feature, not a malfunction in itself, but it means something is preventing the refrigerant from flowing or cooling properly. A technician will need to inspect the outdoor unit to find and fix the root cause before the system can run safely again.

Diagnostic procedure

The full 145 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check open status of the service valve.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 145 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 145

Ranked by how often they cause this code
  1. 1Closed or partially closed service valve
  2. 2Dirty or blocked condenser coil
  3. 3Condenser fan motor failure
  4. 4Overcharged refrigerant circuit
  5. 5Non-condensable gases in the refrigerant circuit

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 145

What does 145 mean on a LG air_conditioner?
Error code 145 on an LG air conditioner indicates that the high-side refrigerant pressure in the Sub2 outdoor unit has risen excessively, causing the system to shut down that unit's compressor as a safety measure. This occurs in three-unit outdoor configurations where the Sub2 unit is one of two subordinate units. The fault protects the compressor and refrigerant circuit from damage caused by extreme pressure conditions. A technician must diagnose the root cause before the system can resume normal operation.
Is error code 145 on an LG air conditioner dangerous?
The error itself represents the system working correctly to prevent a dangerous situation. Excessively high refrigerant pressure can rupture lines, damage the compressor, or cause refrigerant leaks if left unchecked. The compressor shutdown triggered by this fault protects the equipment and prevents a more serious failure. A qualified HVAC technician should evaluate and resolve the cause before the system is returned to service.
How much does it cost to repair error code 145 on an LG air conditioner?
Repair costs vary widely depending on the cause. If the issue is simply a closed service valve or a dirty condenser coil, the cost may be limited to a service call fee in the range of $75 to $200. If a condenser fan motor needs replacement, parts and labor could total between $150 and $450. If the refrigerant circuit requires evacuation and recharge due to contamination or overcharge, expect costs in the range of $200 to $600 or more depending on refrigerant type and quantity.
How do I fix error code 145 on my LG air conditioner?
Start by checking whether the service valve on the Sub2 outdoor unit is fully open, as a closed valve is the most direct cause of this fault. If the valve is open, inspect the condenser coil for dirt or blockage, confirm the condenser fan is spinning correctly, and have a certified technician check the refrigerant charge with manifold gauges. Do not attempt to restart the system repeatedly without addressing the underlying cause, as doing so risks compressor damage.
Will resetting the unit clear error code 145 on an LG air conditioner?
Resetting the unit may temporarily clear the fault and allow a restart, but the error will return if the underlying cause is not corrected. If the condition that drove the high pressure, such as a closed service valve or a blocked condenser, is still present, the compressor will shut down again quickly. Repeated resets without a repair can accelerate wear on the compressor. A proper diagnosis and fix must be performed to permanently clear the code.