mypros+
Error code reference

LG Air Conditioner Error Code 146

Low pressure drop of Sub2 outdoor unit

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the 146 error code actually means

Your LG air conditioning system detected that the pressure inside one of the outdoor units dropped too low, so it automatically shut off that unit's compressor to protect it from damage. This usually means there is a refrigerant problem or a valve that was left closed during servicing. A technician will need to inspect the system before it can run safely again.

Diagnostic procedure

The full 146 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check open status of the service valve.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 146 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 146

Ranked by how often they cause this code
  1. 1Closed or partially closed service valve
  2. 2Low refrigerant charge
  3. 3Restricted or clogged filter drier
  4. 4Faulty or stuck expansion valve
  5. 5Low pressure sensor fault

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 146

What does 146 mean on a LG air_conditioner?
Error code 146 on an LG air conditioner indicates that the Sub2 outdoor unit has experienced an excessive drop in low-side (suction) pressure, causing the compressor to shut down as a protective measure. This applies to three-unit outdoor configurations. The system stops the compressor automatically to prevent internal damage from operating at unsafe pressure levels. A technician needs to identify and correct the cause before the unit can be restarted.
Is it safe to keep running my LG AC when error code 146 appears?
The system has already taken action by shutting off the compressor in the Sub2 outdoor unit, which is the correct protective response. You should not attempt to force the system to run while this fault is active, as operating a compressor under very low suction pressure can cause severe internal damage including loss of lubrication and mechanical failure. Leave the unit off until the fault has been properly diagnosed and resolved.
How much does it cost to repair error code 146 on an LG air conditioner?
Repair costs vary significantly depending on the cause. If a service valve simply needs to be opened, the cost may only be a diagnostic service call fee, typically in the range of $75 to $150. If refrigerant has leaked and the system needs leak repair and recharge, costs can range from $300 to $700 or more depending on refrigerant type and labor. Component replacements such as a filter drier or expansion valve add parts and labor costs on top of that.
Can I fix error code 146 on my LG air conditioner myself?
The first step, checking whether the service valves on the Sub2 outdoor unit are fully open, can be done without specialized tools and is worth verifying before calling for service. However, if the valves are open and the error persists, diagnosing refrigerant levels, sensor function, or component restrictions requires manifold gauges and refrigerant handling certification. Most homeowners should contact a licensed HVAC technician for anything beyond a basic valve check.
Will resetting my LG air conditioner clear error code 146?
A power reset may temporarily clear the fault display, but the error will almost certainly return quickly if the underlying cause has not been addressed. The low pressure condition that triggered the shutdown will still be present, and the compressor protection logic will activate again once the unit attempts to restart. A reset is not a repair and should only be done after the root cause has been identified and corrected.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass