mypros+
Error code reference

LG Air Conditioner Error Code 157

High pressure sensor of sub3 outdoor unit is open or short.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the 157 error code actually means

Your LG air conditioner has detected a problem with a pressure sensor in one of its outdoor units. The sensor either has a broken connection or a wiring fault, and the system has shut down to protect itself. A technician will need to inspect the wiring and sensor to get the unit running again.

Diagnostic procedure

The full 157 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check if sensor is connected to PCB correctly.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 157 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 157

Ranked by how often they cause this code
  1. 1Loose or disconnected sensor connector
  2. 2Faulty high pressure sensor
  3. 3Damaged wiring harness
  4. 4Moisture or corrosion at connector terminals
  5. 5Defective outdoor unit PCB

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 157

What does 157 mean on a LG air_conditioner?
Error code 157 means the high pressure sensor on the sub3 outdoor unit has been detected as open or short circuited. This sensor monitors refrigerant pressure on the high side of the system and sends a signal to the PCB. When that signal falls outside expected parameters, the system logs this code and may disable compressor operation to avoid damage.
Is it safe to keep running my LG AC with error code 157 active?
Running the system while this error is active is not recommended. The high pressure sensor is a critical safety component, and operating without reliable pressure feedback can allow the system to reach damaging or unsafe refrigerant pressures. The system may already be limiting or preventing compressor operation as a protective measure.
Will resetting the unit clear error code 157?
A power reset may temporarily clear the code, but if the underlying fault in the sensor, wiring, or connector is still present, the error will return once the system resumes normal operation. A reset should only be used as part of a diagnostic process, not as a long-term fix. The root cause must be identified and corrected to permanently resolve the error.
Can I fix error code 157 myself?
A knowledgeable DIYer can safely check whether the sensor connector is fully seated on the PCB, which is the first recommended diagnostic step. However, testing sensor resistance, tracing wiring faults, and replacing refrigerant-side components typically requires proper tools and training. If the connector check does not resolve the error, a qualified HVAC technician should be brought in.
How much does it cost to repair error code 157 on an LG air conditioner?
Repair costs vary depending on the root cause. A simple connector reseating during a service call might cost between $75 and $150 for labor alone. Sensor replacement typically adds $50 to $150 in parts. PCB replacement is the most expensive outcome, with parts and labor potentially ranging from $300 to $700 or more depending on the unit and region.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass