mypros+
Error code reference

LG Air Conditioner Error Code 175

Failure of Sub1 constant speed compressor 2 operation

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the 175 error code actually means

Your LG air conditioner has detected that one of its compressors, the second constant speed compressor in the system, is not working properly. The compressor may be mechanically seized, there could be a valve letting refrigerant flow the wrong direction, or the compressor's internal electrical insulation may have broken down. A technician will need to inspect and test the compressor before cooling can be restored.

Diagnostic procedure

The full 175 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check compressor operation when pressing magnetic switch; check check valve direction; measure insulation resistance.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 175 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 175

Ranked by how often they cause this code
  1. 1Compressor mechanical locking
  2. 2Dielectric breakdown of compressor windings
  3. 3Check valve leakage
  4. 4Magnetic contactor failure
  5. 5Refrigerant system pressure imbalance

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 175

What does 175 mean on a LG air_conditioner?
Error code 175 means the system has detected a failure in the Sub1 constant speed compressor 2 operation. The code can be triggered by three conditions: mechanical compressor locking, check valve leakage in the refrigerant circuit, or dielectric breakdown of the compressor motor windings. This error applies to LG multi-compressor systems and requires hands-on diagnostic testing to identify the specific root cause.
Is it safe to keep running my LG air conditioner when error code 175 is displayed?
You should not attempt to continue operating the system with error code 175 active. Dielectric breakdown in a compressor poses an electrical safety risk, and a mechanically locked compressor can draw excessive current and cause additional component damage. The system controller typically disables the affected compressor circuit for this reason, so continued operation attempts may worsen the underlying fault.
Will resetting my LG air conditioner clear error code 175?
A power reset may temporarily clear the error code from the display, but the underlying mechanical or electrical fault will remain. If the compressor is locked, has dielectric breakdown, or the check valve is leaking, the error will return as soon as the system attempts to run that compressor again. Resetting without repair is not a solution and could mask the fault while allowing further damage to occur.
Can I fix error code 175 on my LG air conditioner myself?
The diagnostics and repairs required for error code 175 are not suitable for most homeowners. Checking a magnetic contactor, measuring insulation resistance with a megohmmeter, and evaluating refrigerant circuit check valves all require specialized tools and technical knowledge. Additionally, any work involving refrigerant circuits legally requires EPA Section 608 certification in the United States. A qualified HVAC technician should perform the diagnosis and repair.
How much does it cost to repair error code 175 on an LG air conditioner?
Repair costs vary significantly depending on the root cause. If the issue is a failed check valve or magnetic contactor, costs are typically in the range of $150 to $500 including parts and labor. Compressor replacement in a commercial or multi-compressor LG system is considerably more expensive, often ranging from $800 to $2,500 or more depending on the unit and refrigerant recovery requirements. A technician will need to diagnose the specific cause before providing an accurate estimate.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass