mypros+
Error code reference

LG Air Conditioner Error Code 29

Inverter compressor over current

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the 29 error code actually means

Your LG air conditioner detected that the outdoor compressor was pulling too much electrical current and shut itself off to prevent damage. This is usually caused by something making the compressor work harder than it should, such as blocked refrigerant lines, a refrigerant charge problem, or a stuck expansion valve. A technician will need to check the refrigerant system and electrical components to find and fix the root cause.

Diagnostic procedure

The full 29 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check compressor locking, check compressor wire open/short, check insulation, check outdoor fan, check IPM.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 29 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 29

Ranked by how often they cause this code
  1. 1Refrigerant pressure abnormality
  2. 2EEV (Electronic Expansion Valve) malfunction or disconnected connector
  3. 3Blocked or kinked refrigerant piping
  4. 4Restricted outdoor unit airflow
  5. 5Failing compressor windings

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 29

What does 29 mean on a LG air conditioner?
Error code 29 indicates that the outdoor unit inverter compressor has exceeded its maximum allowable input current of 46 amps. The system shuts down automatically to protect the compressor and inverter components from damage. This fault points to a condition in the refrigerant circuit or compressor itself that is causing abnormally high electrical load. A technician will need to inspect refrigerant pressures, the expansion valve, line routing, and compressor condition.
Is it safe to keep running my LG air conditioner with error code 29?
No. Error code 29 is a protective shutdown triggered by overcurrent conditions that could damage the compressor or inverter board if the unit continued running. The system locks out specifically to prevent this damage. Attempting to force the unit back on repeatedly without resolving the cause risks burning out the compressor, which is a significantly more expensive repair.
How much does it cost to repair error code 29 on an LG air conditioner?
Repair cost depends heavily on the root cause. A refrigerant adjustment or line correction might run between $150 and $400 including labor. An EEV replacement typically falls in the $200 to $600 range depending on parts and labor rates. A compressor replacement is the most expensive outcome, generally ranging from $800 to $2,000 or more depending on the system size and refrigerant type.
Can I fix error code 29 on my LG air conditioner myself?
Some preliminary checks are within reach of a capable DIYer, such as confirming the outdoor unit is not blocked or covered and verifying the EEV wiring connector is fully seated and free of corrosion. However, checking refrigerant pressures requires certified equipment and EPA 608 certification to handle refrigerants legally. If the pressure system or compressor is at fault, a licensed HVAC technician should complete the repair.
Will resetting my LG air conditioner clear error code 29?
A power reset may temporarily clear the fault and allow the unit to restart, but if the underlying cause is not corrected, the error code will return, typically within the same operating cycle. Repeated resets without diagnosis can accelerate wear on the compressor and inverter components. The fault should be properly diagnosed and repaired before relying on the unit for regular operation.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass