What the 39 error code actually means

Your LG air conditioner has detected an internal communication problem inside the outdoor unit's main control board. Two computer chips on that board have stopped talking to each other correctly, which prevents the system from safely running the compressor. This typically requires a technician to inspect or replace the outdoor control board.

Diagnostic procedure

The full 39 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check PFC Micom and INV Micom software program versions; replace inverter PCB assembly if abnormal.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 39 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 39

Ranked by how often they cause this code
  1. 1Firmware version mismatch between PFC Micom and INV Micom
  2. 2Failed or corrupted inverter PCB
  3. 3Solder joint or connector failure on the inverter PCB
  4. 4Voltage supply irregularity to the inverter PCB
  5. 5Physical damage to the inverter PCB

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 39

What does 39 mean on a LG air_conditioner?
Error code 39 indicates a transmission error between the PFC Micom and the INV Micom on the outdoor unit's inverter PCB. These are two microcontrollers on the same board that must communicate to coordinate compressor and power factor correction operation. When that internal communication fails, the system shuts down and displays this code. A software version mismatch or a faulty inverter PCB are the most common causes.
Will resetting my LG air conditioner clear error code 39?
A power reset may temporarily clear the error if the communication failure was caused by a transient condition such as a voltage fluctuation. However, if the root cause is a firmware mismatch or a damaged inverter PCB, the error will return shortly after the unit attempts to restart. A reset alone is not a repair for this fault.
How much does it cost to repair LG air conditioner error code 39?
If the issue is a firmware version mismatch that can be corrected without parts, you would pay only for a service call and diagnostic time. If the inverter PCB assembly requires replacement, total repair costs including parts and labor typically range from a few hundred dollars to over a thousand dollars, depending on the unit model and local labor rates. Getting a diagnosis from a qualified technician before authorizing parts replacement is advisable.
Can I fix error code 39 on my LG air conditioner myself?
Basic checks such as power cycling the unit or verifying that nothing has physically disturbed the outdoor unit are reasonable first steps. However, resolving error 39 typically requires checking firmware version compatibility on the inverter PCB or replacing the board, both of which involve working inside a high-voltage outdoor unit. This work is best performed by a qualified HVAC technician.
Is it safe to keep running my LG air conditioner when error 39 is showing?
No. Error 39 causes the system to shut down the compressor because reliable communication between the two inverter control processors cannot be confirmed. Attempting to force the unit to run in this condition could result in uncontrolled inverter operation and potential damage to the compressor or other components. The unit should remain off until the fault is diagnosed and corrected.