What the 40 error code actually means

Your LG air conditioner has detected a problem with a small sensor in the outdoor unit that monitors the electrical current going to the compressor. The system's control board checked this sensor when power was first applied and got a reading outside the expected range, so it shut things down to prevent damage. This could be caused by low or unstable power from your electrical supply, a faulty sensor, or a wiring issue in the outdoor unit.

Diagnostic procedure

The full 40 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check input voltage R~S/S~T/T~R is 380V ±10%; if normal, check inverter PCB assembly.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 40 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 40

Ranked by how often they cause this code
  1. 1Abnormal supply voltage at the outdoor unit
  2. 2Faulty CT sensor
  3. 3Loose or damaged CT sensor wiring
  4. 4Failed inverter control board
  5. 5Tripped or undersized circuit breaker causing voltage drop

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 40

What does 40 mean on a LG air conditioner?
Error code 40 indicates a fault with the inverter compressor CT sensor in the outdoor unit. The system's Micom control board checks the CT sensor input voltage at the moment power is applied and expects a reading of 2.5V plus or minus 0.3V. When that voltage is outside the 2.2V to 2.8V range, the unit shuts down and displays this code. Causes include abnormal supply voltage, a failed CT sensor, damaged wiring, or a faulty inverter board.
Is it safe to keep running my LG air conditioner when error code 40 appears?
No. When error code 40 is active, the system prevents operation specifically to protect the compressor and inverter components from damage caused by unmonitored current conditions. Attempting to force the unit to run while this fault is present could result in compressor damage or electrical hazards. The fault should be diagnosed and resolved before resuming normal operation.
How much does it cost to repair error code 40 on an LG air conditioner?
Repair costs vary depending on the root cause. If the issue is simply an electrical supply problem corrected at the breaker or panel, costs may be limited to a service call fee, typically in the range of $75 to $150. CT sensor replacement parts and labor can run from $150 to $350 depending on the model and your location. An inverter control board replacement is more involved, often ranging from $300 to $600 or more for parts and labor combined.
Can I fix error code 40 on my LG air conditioner myself?
The first step, checking the L1-L2 supply voltage at the outdoor unit terminal block, can be done by a confident DIYer with a multimeter and appropriate safety precautions. However, diagnosing and replacing the CT sensor or inverter control board involves working inside the outdoor unit with high-voltage components and should be handled by a qualified technician. Incorrect handling of inverter circuitry can cause serious injury.
Will resetting my LG air conditioner clear error code 40?
A power reset may temporarily clear the code, but if the underlying cause, such as a faulty CT sensor, wiring fault, or supply voltage problem, has not been corrected, the error will return immediately or shortly after the next startup. The Micom checks the CT sensor voltage during every initial power-up sequence, so the fault will reappear as long as the root cause remains.