mypros+
Error code reference

LG Air Conditioner Error Code 41

Inverter compressor discharge pipe temperature sensor fault

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the 41 error code actually means

Your LG air conditioner has detected a problem with a small temperature sensor located on the compressor in the outdoor unit. This sensor tells the system how hot the compressor is running, and the unit has shut down because it is getting an invalid reading from that sensor. The issue is usually a failed sensor, a loose wire connection, or damaged wiring rather than a problem with the compressor itself.

Diagnostic procedure

The full 41 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check sensor connection to PCB; check sensor resistance (error if >5MΩ open or <2kΩ short).
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 41 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 41

Ranked by how often they cause this code
  1. 1Failed discharge temperature sensor (thermistor)
  2. 2Loose or corroded sensor connector at the PCB
  3. 3Damaged sensor wiring
  4. 4Moisture intrusion into the sensor connector
  5. 5Faulty outdoor unit PCB

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 41

What does 41 mean on a LG air conditioner?
Error code 41 indicates a fault with the outdoor unit inverter compressor discharge temperature sensor. The system has detected either an open circuit or a short circuit in the sensor circuit, which produces an invalid temperature reading. As a protective measure, the unit stops operating until the fault is resolved. The problem typically involves the sensor itself, its connector, or the wiring connecting it to the outdoor PCB.
Is it safe to keep running my LG air conditioner with error code 41?
The unit will typically shut itself down when error code 41 is active, which is a built-in protection to prevent compressor damage from unmonitored discharge temperatures. You should not attempt to bypass or override this shutdown. Continuing to operate the system without a functioning discharge temperature sensor risks serious and costly compressor damage.
Will resetting my LG air conditioner clear error code 41?
A power reset may temporarily clear the error code and allow the unit to restart, but if the underlying fault with the sensor, wiring, or connector has not been corrected, the code will return quickly. Repeated resets without addressing the root cause will not fix the problem and may allow the compressor to operate without proper temperature protection. The fault should be diagnosed and repaired before returning the unit to normal service.
Can I fix error code 41 on my LG air conditioner myself?
Checking and reseating the sensor connector at the outdoor PCB is a task many experienced DIYers can handle safely with the unit powered off. Measuring sensor resistance with a multimeter is also straightforward if you are comfortable with basic electrical testing. However, replacing the discharge temperature sensor or the PCB involves working inside the outdoor unit and may require handling refrigerant lines, so professional service is recommended if you are unsure about electrical work.
How much does it cost to repair error code 41 on a LG air conditioner?
If the repair only requires cleaning or reseating a connector, the cost is minimal. Replacing the discharge temperature sensor itself is generally inexpensive, with parts typically ranging from around $15 to $60 and a service call adding labor costs on top. If the outdoor PCB has failed, expect total repair costs in the range of $200 to $600 or more depending on the model and local labor rates.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass