LG Air Conditioner Error Code 44

44LG Air Conditioner

What this code means

Outdoor unit air temperature sensor error (sensor measured value not normal, open/short).

First step from the service manual

Check temp sensor connecting condition and lead wire connecting condition. Check whether temp sensor resistance value is normal: 10°C = 20.7kΩ, 25°C = 10kΩ, 50°C = 3.4kΩ.

Next steps: diagnose the root cause

1
Verify the error code is active

Power cycle the unit and see if the code returns. If it does, the fault is persistent and requires diagnosis.

2
Get the full diagnostic procedure

Get step-by-step guidance, test values, and wiring diagrams from the OEM service manual.

Start diagnosing 44 on your LG air conditioner

$29/month · Cancel anytime · Or $9.95 3-day pass

What’s available for LG air conditioner models

Access LG air conditioner service manuals, wiring schematics, exploded parts views, and error code references on MyPros+.

Related LG air conditioner error codes