What this code means
DC peak current error — IPM current reached 35A ±3A, or DC link voltage dropped below DC 140V, or outdoor fan lock detected (outdoor pipe temp over 65°C while compressor operating); occurs if fault happens 5 times within 1 hour.
First step from the service manual
Check connecting cable (3 lines) between indoor and outdoor, check CN-UVW connector state, check IPM power module for short (P-N, P-U, V, W, N-U, V, W), check supplied voltage and DC link voltage, check refrigerant pressure.
Next steps: diagnose the root cause
Power cycle the unit and see if the code returns. If it does, the fault is persistent and requires diagnosis.
Get step-by-step guidance, test values, and wiring diagrams from the OEM service manual.
$29/month · Cancel anytime · Or $9.95 3-day pass
What’s available for LG air conditioner models
Access LG air conditioner service manuals, wiring schematics, exploded parts views, and error code references on MyPros+.
Related LG air conditioner error codes
Start diagnosing faster today.
$29/month · Cancel anytime · Or $9.95 3-day pass