LG Air Conditioner Error Code CH65

Heatsink thermistor open or short circuit.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the CH65 error code actually means

Your LG air conditioner has detected a problem with a small temperature sensor located on the part of the unit that keeps the electronics cool. The sensor is either broken internally or has a wiring problem, so the system cannot safely monitor its own electronics and has shut down. A technician will need to test and likely replace the sensor or its wiring to restore normal operation.

Diagnostic procedure

The full CH65 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
Confirm the fault
Power cycle the unit: switch off the breaker for 60 seconds, then restore power. If the code returns, the fault is persistent and the procedure below isolates the cause.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock CH65 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of CH65

Ranked by how often they cause this code
  1. 1Failed heatsink thermistor
  2. 2Disconnected or loose thermistor connector
  3. 3Damaged wiring harness
  4. 4Moisture or contamination at the connector
  5. 5Faulty control board

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about CH65

What does CH65 mean on a LG air_conditioner?
CH65 indicates an open or short circuit in the heatsink thermistor, which is the temperature sensor mounted on the inverter module's heatsink. The control board monitors this sensor to protect the compressor drive electronics from overheating. When the sensor signal falls outside the valid resistance range, the unit shuts down and displays CH65. The fault points to either a failed sensor, damaged wiring, or a loose connector.
Is it safe to keep running my LG air conditioner with a CH65 code?
No. The CH65 fault causes the unit to shut down precisely because the control board can no longer monitor heatsink temperature. Attempting to bypass or ignore this fault could allow the inverter electronics to overheat without protection, potentially causing permanent damage to the inverter module or creating a fire hazard. Leave the unit off until the fault is diagnosed and repaired.
How much does it cost to repair a CH65 fault on an LG air conditioner?
Repair costs vary depending on which component has failed. A thermistor replacement is generally an inexpensive part, with total repair costs typically ranging from around $80 to $200 including labor. If the control board requires replacement, costs can range from $250 to $600 or more depending on the model and local labor rates. Getting a diagnostic visit from a certified technician will give you a precise estimate for your specific unit.
Can I fix CH65 on my LG air conditioner myself?
A knowledgeable DIYer can check for a disconnected thermistor connector and reseat it, which requires no parts and may resolve the fault if the connection was simply loose. Testing the thermistor's resistance with a multimeter is also within reach for someone comfortable with basic electrical diagnostics. However, replacing the thermistor or the control board involves working near high-voltage inverter components, and that work is best handled by a qualified technician.
Will resetting my LG air conditioner clear the CH65 error?
A power reset may temporarily clear the fault code and allow the unit to restart, but CH65 will return if the underlying problem with the thermistor or its wiring has not been corrected. Repeated resets without repairing the root cause can put the inverter components at risk. A reset is only appropriate as part of a diagnostic process after a repair has been made.