What the E180 error code actually means

Your LG air conditioner has detected that two internal refrigerant control valves, which should never be open at the same time, were both open simultaneously. The system has automatically stopped and will try to restart itself to see if the problem is still there. If the issue continues after the restart, a technician will need to inspect the valves and their wiring.

Diagnostic procedure

The full E180 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
System restarts automatically after making an automatic stop to check.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E180 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E180

Ranked by how often they cause this code
  1. 1Faulty solenoid valve failing to close
  2. 2Short circuit in valve control wiring
  3. 3Defective MCU sending incorrect output signals
  4. 4Valve coil electrical resistance fault
  5. 5Intermittent connector or terminal corrosion

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E180

What does E180 mean on a LG air_conditioner?
E180 means the system has detected that both the cooling and heating MCU solenoid valves opened at the same time, which is not a normal or safe operating condition. These two valves are supposed to operate exclusively of each other to route refrigerant in the correct direction. The system responds by stopping automatically and attempting a restart to recheck whether the fault is still present. If the simultaneous valve opening is confirmed on the next cycle, the fault will persist and require hands-on diagnosis.
Is it safe to continue using my LG air conditioner with an E180 error?
You should not attempt to continue running the unit while the E180 fault is active or recurring. Simultaneous opening of both refrigerant control valves can disrupt refrigerant flow in ways that may damage the compressor or other sealed system components over time. The automatic stop the unit performs is a protective measure, and bypassing or repeatedly resetting through it without addressing the cause risks further damage.
How much does it cost to repair an LG air conditioner E180 error?
Repair costs will vary depending on the root cause identified during diagnosis. If the issue is a corroded connector or a wiring short, repair costs may fall in a lower range covering labor only, typically somewhere between $75 and $200. Replacing a faulty solenoid valve coil or valve assembly can run between $150 and $400 depending on the unit model and parts availability. If the MCU itself needs replacement, costs can range from $300 to $600 or more, including parts and labor.
Will the LG air conditioner fix itself after an E180 error?
The system is designed to perform an automatic stop and then restart to recheck the valve states as part of its first-detection response. If the fault was caused by a brief transient electrical event, the system may recover on its own after the restart. However, if an underlying mechanical or electrical problem exists with the solenoid valves, wiring, or MCU, the error will return and the unit will need a technician to diagnose and repair the root cause.
Will resetting the unit clear the E180 error code?
The system already performs an automatic reset as part of its first-detection procedure for E180. A manual power cycle may temporarily clear the displayed code, but if the underlying fault with the solenoid valves or their control circuitry is still present, the error will return once the system attempts to switch between cooling and heating modes again. A proper repair of the faulty component is required to clear the code permanently.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass