LG Air Conditioner Error Code E185

Cross wiring error between communication and power cable of indoor unit.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E185 error code actually means

Your LG air conditioner has detected that its power wires and communication wires have been mixed up or connected to the wrong terminals. This is a wiring problem, not a broken part, and it needs to be corrected before the system can run safely. A qualified technician should inspect and correct the wiring connections to resolve this error.

Diagnostic procedure

The full E185 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check for power input (220V) at the terminal block (F1/F2); check for disconnected line after turning off main power.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E185 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E185

Ranked by how often they cause this code
  1. 1Swapped power and communication wires at the terminal block
  2. 2Incorrect wiring after a previous repair or reinstallation
  3. 3Damaged wiring harness causing conductor contact between circuits
  4. 4Loose or displaced terminal connections
  5. 5Faulty or damaged indoor unit control board

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E185

What does E185 mean on a LG air_conditioner?
E185 on an LG air conditioner indicates a cross wiring error between the communication cable and the power cable of the indoor unit. The system has detected that these two circuits are mixed up or incorrectly connected at the terminal block. This is a wiring fault that must be corrected before the unit can operate safely. Do not attempt to run the system while this error is active.
Is it safe to use my air conditioner while E185 is displayed?
No, you should not operate the unit while E185 is active. A cross wiring condition means 220V power may be present on terminals or conductors where it should not be, which poses a risk of equipment damage, control board failure, or electrical hazard. Turn off the unit at the main disconnect until the wiring issue is diagnosed and corrected.
How much does it cost to repair an E185 error on an LG air conditioner?
If the issue is simply a wiring correction at the terminal block, repair costs are typically limited to a service call fee, which can range from around $75 to $200 depending on your location and the technician. If the wiring harness is damaged and needs replacement, parts and labor could bring the total to a range of $150 to $400 or more. In the uncommon scenario where the indoor unit control board has been damaged by the cross wiring condition, board replacement can add significantly to the cost.
Can I fix the E185 error myself?
If you are comfortable working with electrical systems and can safely identify wiring diagrams, you may be able to inspect and correct the terminal block connections after turning off main power. However, because 220V power is involved at the F1 and F2 terminals, this repair carries a significant shock risk if proper precautions are not followed. Most homeowners should have a qualified HVAC technician perform this diagnostic and correction.
Will resetting the unit clear the E185 error?
Resetting the unit by cycling power will not clear E185 if the underlying wiring problem has not been fixed. The error will return immediately or shortly after power is restored because the control board will detect the same wiring condition again. The wiring connections must be inspected and corrected at the terminal block to resolve the fault.