LG Air Conditioner Error Code E190

No temperature changes in EVA IN during pipe inspection or changes in temperature seen in indoor unit with wrong address.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E190 error code actually means

Your LG air conditioner detected a problem during its internal self-check, specifically that the temperature at the refrigerant inlet on the indoor unit did not change as expected. This could mean a sensor has failed, the refrigerant is not flowing properly, or the unit may have been set up with an incorrect address in a multi-room system. A technician will need to inspect the temperature sensor, wiring, and system configuration to resolve this.

Diagnostic procedure

The full E190 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
Confirm the fault
Power cycle the unit: switch off the breaker for 60 seconds, then restore power. If the code returns, the fault is persistent and the procedure below isolates the cause.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E190 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E190

Ranked by how often they cause this code
  1. 1Faulty EVA IN thermistor
  2. 2Incorrect indoor unit address configuration
  3. 3Disconnected or damaged sensor wiring
  4. 4Low refrigerant charge
  5. 5Defective indoor unit PCB

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E190

What does E190 mean on a LG air_conditioner?
E190 on an LG air conditioner indicates a pipe inspection fault where no temperature change was detected at the evaporator inlet (EVA IN) sensor during the system's self-check routine. It can also appear when temperature changes are being reported by an indoor unit configured with an incorrect address in a multi-zone installation. The error points to a problem with the EVA IN thermistor, refrigerant flow, wiring, or system addressing.
Is it safe to keep running my LG air conditioner with an E190 error?
Continuing to operate the unit with E190 active is not recommended. The error indicates the system cannot confirm proper refrigerant flow or temperature behavior at the evaporator inlet, which could mask underlying issues like low refrigerant or a failing component. Running the system under these conditions risks further damage to the compressor or other components.
How much does it cost to repair an E190 error on an LG air conditioner?
Repair costs depend on the root cause. Reconfiguring an address setting is typically inexpensive and may only involve a service call fee, generally in the range of $75 to $150. Replacing an EVA IN thermistor usually falls in the $100 to $250 range including parts and labor. Refrigerant recharge or PCB replacement will cost more, often between $200 and $600 or higher, depending on system size and local labor rates.
Can I fix error code E190 on my LG air conditioner myself?
Some causes of E190, such as an incorrect indoor unit address setting, can be corrected without special tools if you are comfortable navigating the system's configuration menu. However, checking the EVA IN thermistor resistance, inspecting wiring connections, and assessing refrigerant charge all require technical knowledge and, in the case of refrigerant work, EPA certification. Most homeowners should contact a qualified HVAC technician for this repair.
Will resetting my LG air conditioner clear the E190 error?
A power reset may temporarily clear the error, but if the underlying cause, such as a faulty sensor, wiring fault, or incorrect address, has not been corrected, the E190 code will return once the system runs its pipe inspection routine again. A reset should be used as part of the diagnostic process, not as a fix on its own.