LG Air Conditioner Error Code E213

Indoor unit assigned on MCU is not installed even though total count matches.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E213 error code actually means

Your LG air conditioning system expected to find a specific indoor unit in a particular spot on the network, but it could not communicate with it, even though the right number of units appear to be connected overall. This usually means a configuration setting or wiring connection in the system's controller needs to be corrected. A technician will need to check the address settings and connections inside the branch controller to resolve this.

Diagnostic procedure

The full E213 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check MCU DIP switch settings and reassemble branch part.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E213 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E213

Ranked by how often they cause this code
  1. 1Incorrect MCU DIP switch settings
  2. 2Incorrect branch controller DIP switch settings
  3. 3Loose or improper branch controller wiring connections
  4. 4Indoor unit communication board failure
  5. 5System topology changed without MCU reconfiguration

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E213

What does E213 mean on a LG air_conditioner?
E213 indicates that the MCU (Master Control Unit) has an indoor unit assigned to a specific address in its configuration that is not responding, even though the total number of connected units matches the expected count. This is a network address mismatch fault common in multi-zone LG systems. The root cause is typically incorrect DIP switch settings on the MCU or branch controller, or a loose communication connection at the branch assembly.
Is it safe to keep running my LG air conditioner with an E213 error?
E213 is a configuration and communication fault rather than a refrigerant or electrical safety hazard, so it does not pose an immediate danger. However, the indoor unit assigned to the missing address will not operate correctly, meaning some zones may have no heating or cooling. It is best to have the fault diagnosed and corrected promptly to restore full system function.
How much does it cost to repair an E213 error on an LG multi-zone system?
If the fix only requires correcting DIP switch settings and reassembling branch connections, repair costs are typically limited to a technician service call, which can range from $80 to $200 depending on your area. If a faulty indoor unit communication board needs to be replaced, total costs including parts and labor can range from $150 to $500 or more. Getting a diagnostic visit first will clarify whether parts are needed.
Can I fix E213 myself or do I need a technician?
Resolving E213 requires accessing the MCU and branch controller DIP switches, which involves working inside the system's control enclosures. While an experienced DIYer familiar with multi-zone systems may be able to audit and correct DIP switch settings, this task is generally best handled by a qualified HVAC technician who can cross-reference the system wiring diagram and configuration layout. Incorrect DIP switch changes can cause additional communication faults across the system.
Will resetting the system clear the E213 error?
A simple power reset is unlikely to permanently clear E213 because the fault is caused by a configuration mismatch or a physical connection issue, not a temporary software glitch. The MCU will re-detect the missing unit assignment after restarting and re-display the error. The underlying DIP switch configuration or wiring issue must be corrected before the error will clear.