mypros+
Error code reference

LG Air Conditioner Error Code E366

Error due to over voltage/low voltage of inverter PBA2.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E366 error code actually means

Your LG air conditioner has detected that the electrical voltage coming into one of its main control boards is either too high or too low to operate safely. This is a power supply issue that could involve the building's electrical system or the unit's internal components. A qualified technician needs to measure the incoming voltage and inspect the wiring before the unit can safely be restarted.

Diagnostic procedure

The full E366 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Power off and check 380V between R,S,T terminal blocks.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E366 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E366

Ranked by how often they cause this code
  1. 1Utility supply voltage out of range
  2. 2Loose or corroded terminal block connections
  3. 3Phase loss or phase imbalance
  4. 4Undersized or damaged supply wiring
  5. 5Failed inverter PBA2

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E366

What does E366 mean on a LG air_conditioner?
E366 indicates that the second inverter control board (PBA2) has detected either an over-voltage or low-voltage condition on its power supply input. This error is specific to three-phase systems operating on a 380V supply connected at the R, S, and T terminal blocks. The board's internal protection circuit shuts the unit down to prevent damage to the inverter and compressor. The first step is to power off the unit and verify correct voltage at all three terminal blocks.
Is it safe to keep using my LG air conditioner when E366 is displayed?
No, you should not attempt to operate the unit while E366 is active. The error indicates a voltage condition that is outside safe operating limits for the inverter board and compressor. Continuing to run the unit could cause serious damage to the inverter PBA2, the compressor, or both. Power the system off and have a technician inspect the electrical supply before restarting.
How much does it cost to repair an LG air conditioner showing E366?
Repair costs vary depending on the root cause. If the issue is a loose terminal connection or an upstream wiring problem, the repair may cost relatively little, typically in the range of a standard service call fee. If the inverter PBA2 board itself has failed and needs replacement, parts and labor costs can range from several hundred to over a thousand dollars depending on the model and part availability. A technician will need to diagnose the supply voltage first before an accurate estimate can be given.
Can I fix the E366 error myself?
Diagnosing E366 requires measuring three-phase 380V supply voltage, which is hazardous and should only be performed by a qualified electrician or HVAC technician. A technician can check terminal connections and measure incoming voltage to determine whether the issue is with the building's electrical supply or the inverter board itself. If the board has failed, it must be replaced by a professional. This is not a DIY repair.
Will resetting the unit clear the E366 error code?
A power reset may temporarily clear the fault display, but the error will return if the underlying voltage problem has not been corrected. Simply resetting the unit without addressing the supply voltage or wiring issue does not fix the root cause. The system needs to be inspected and the voltage at the R, S, and T terminals confirmed to be within normal range before the error will stay cleared.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass