mypros+
Error code reference

LG Air Conditioner Error Code E425

Phase reversal or phase failure on 3-phase outdoor unit wiring (R-S-T-N), connection error on 3-phase input.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E425 error code actually means

Your LG air conditioner's outdoor unit runs on a special 3-phase electrical supply, and this error means the power coming in is either connected in the wrong order or one of the power legs is missing. The system automatically shuts down to protect its compressor from serious damage. This is an electrical supply issue that requires a licensed electrician or HVAC technician to diagnose and correct.

Diagnostic procedure

The full E425 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check voltage for L1-L2/L1-L3/L2-L3, check phase with 3-phase tester.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E425 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E425

Ranked by how often they cause this code
  1. 1Incorrect phase wiring sequence at the terminal block
  2. 2Phase failure due to a blown fuse or tripped breaker on one leg
  3. 3Loose or corroded connection at the disconnect or terminal block
  4. 4Utility supply phase loss or significant phase voltage imbalance
  5. 5Faulty phase detection circuit or control board

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E425

What does E425 mean on a LG air_conditioner?
E425 indicates a phase reversal or phase failure on the 3-phase power supply to the LG outdoor unit. The system monitors the R-S-T-N power input and shuts down when it detects that the phase sequence is incorrect or that one or more phases are missing. This is a protective fault designed to prevent compressor damage from reverse rotation or single-phasing.
Is it safe to keep running my AC when E425 appears?
No. The unit will not operate when E425 is active because doing so could destroy the compressor within minutes. Phase reversal causes the compressor motor to run backward, and phase failure causes it to run on reduced power with extreme heat buildup. The system's automatic shutdown is a critical protection feature and should not be bypassed.
How much does it cost to repair an E425 error on an LG commercial AC?
Repair costs vary depending on the root cause. If the fix only requires rewiring the phase connections at the terminal block, expect to pay for a service call plus labor, typically in the range of $150 to $350. If a fuse block, disconnect switch, or control board needs replacement, costs can range from $300 to over $800 depending on parts and local labor rates. Utility-side phase issues are typically resolved by the power company at no cost to the customer.
Can I fix E425 myself, or do I need a professional?
Diagnosing and correcting E425 involves working with 3-phase high-voltage electrical supply, which is dangerous without proper training and equipment. A licensed electrician or certified HVAC technician should check line-to-line voltages and phase rotation using a 3-phase tester before any wiring changes are made. If the issue is on the utility supply side, the technician will coordinate with the power company to resolve it.
Will resetting the unit clear the E425 error?
A simple power reset will not permanently clear E425 if the underlying electrical supply problem still exists. The unit will detect the fault again on startup and re-trigger the error. The phase sequence and line voltages must be corrected first, and then the unit can be powered back on and allowed to restart normally.