mypros+
Error code reference

LG Air Conditioner Error Code E439

Refrigerant leakage error

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E439 error code actually means

Your LG air conditioner has detected a problem with both of its internal pressure monitors at the same time, which usually points to a refrigerant leak or a wiring issue. Low refrigerant can cause the system to lose efficiency and may damage the compressor if the unit keeps running. A technician will need to inspect the wiring and check the refrigerant levels to determine the root cause.

Diagnostic procedure

The full E439 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check if high/low pressure connector is disconnected from PCB; check refrigerant level; check 5V at sensor terminals.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E439 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E439

Ranked by how often they cause this code
  1. 1Low or depleted refrigerant charge
  2. 2Disconnected pressure sensor connector at the PCB
  3. 3Missing or incorrect 5V supply at sensor terminals
  4. 4Damaged or corroded sensor wiring harness
  5. 5Failed PCB pressure sensor input circuit

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E439

What does E439 mean on a LG air_conditioner?
E439 is a refrigerant leakage error that occurs when both the high-pressure and low-pressure sensors malfunction or report abnormal readings at the same time. The control board flags simultaneous failure of both sensors as a likely sign of refrigerant loss, since a single failed sensor would produce a different error. The code can also be caused by a disconnected sensor connector or a loss of the 5V power supply that both sensors depend on.
Is it safe to keep running my LG air conditioner when E439 is displayed?
Running the unit continuously with an active E439 code is not recommended. If the error reflects a true refrigerant leak, operating the system with low refrigerant can overheat and damage the compressor, leading to a much more expensive repair. Turn the unit off and address the error before resuming normal use.
Will resetting my LG air conditioner clear the E439 error?
A power reset may temporarily clear the E439 code, but if the underlying problem, whether a refrigerant leak, bad wiring, or missing 5V supply, has not been resolved, the error will return once the system restarts and attempts to read the sensors. A reset is useful as a starting point to confirm whether the fault is persistent, but it should not be treated as a fix on its own.
Can I fix E439 on my LG air conditioner myself?
Some causes of E439 can be addressed without professional help, such as reseating a disconnected pressure sensor connector at the PCB or checking the wiring harness for visible damage. However, if the root cause is a refrigerant leak, handling refrigerant requires EPA certification and specialized equipment, so that portion of the repair must be performed by a licensed HVAC technician. Start with the wiring and connector inspection before assuming a refrigerant issue.
How much does it cost to repair an E439 error on an LG air conditioner?
Repair costs vary depending on the cause. A simple wiring connector fix may cost very little, while a refrigerant leak repair involving leak detection, system evacuation, and recharge can range from roughly 200 to 600 dollars or more depending on the refrigerant type and leak location. A PCB replacement, if the input circuit has failed, typically falls in the range of 150 to 400 dollars for parts and labor.

78,000+ service manuals · 160,000+ error codes · 55+ brands