What the E451 error code actually means

Your LG air conditioner has detected that the refrigerant pressure inside the system has dropped too low to operate safely, and it has shut itself down to prevent damage. This is most often caused by a refrigerant leak, but could also be a faulty pressure sensor. The unit will not run normally until the root cause is found and repaired.

Diagnostic procedure

The full E451 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
Confirm the fault
Power cycle the unit: switch off the breaker for 60 seconds, then restore power. If the code returns, the fault is persistent and the procedure below isolates the cause.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E451 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E451

Ranked by how often they cause this code
  1. 1Refrigerant leak
  2. 2Faulty low pressure switch
  3. 3Clogged filter drier or restricted expansion valve
  4. 4Outdoor unit operating in very low ambient temperature
  5. 5Open or loose refrigerant service valve

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E451

What does E451 mean on a LG air_conditioner?
E451 indicates a low pressure switch fault on the second detection circuit of the refrigerant system. The unit has detected that suction pressure has dropped below a safe operating threshold and has shut the compressor down to prevent damage. This fault most commonly points to a low refrigerant charge caused by a leak, though a faulty pressure switch or a refrigerant restriction can also trigger it.
Is it safe to keep running my LG air conditioner with an E451 error?
No. The E451 fault causes the unit to shut down the compressor specifically to prevent mechanical damage from low-pressure operation. Repeatedly attempting to restart and run the system without addressing the root cause can lead to compressor failure, which is a significantly more expensive repair. Leave the unit off until the fault is diagnosed and corrected.
Will resetting my LG air conditioner clear the E451 error?
A power reset may temporarily clear the fault display, and the unit may attempt to restart. However, if the underlying cause such as low refrigerant charge or a faulty pressure switch has not been corrected, the E451 fault will return quickly once the system tries to operate. A reset is useful for confirming the fault is active and repeatable, but it is not a repair.
Can I fix E451 on my LG air conditioner myself?
Some preliminary checks, such as verifying that service valves are open and that ambient temperatures are within the unit's operating range, can be done without special tools. However, diagnosing and repairing the most common cause, a refrigerant leak, requires EPA-certified technicians and specialized equipment in most regions. Replacing a low pressure switch also involves recovering refrigerant, so professional service is strongly recommended for this fault.
How much does it cost to repair an E451 error on an LG air conditioner?
Repair costs vary widely depending on the cause. Refrigerant leak detection and recharge can range from around 200 to 600 dollars or more depending on leak location, system size, and refrigerant type. A low pressure switch replacement is generally less expensive, typically in the range of 100 to 300 dollars including labor. If a refrigerant restriction requires replacing the filter drier or expansion valve, costs can be higher.