mypros+
Error code reference

LG Refrigerator Error Code OF r

Fridge-Off Forced Operation-compressor at 3600 RPM, fridge compartment off for checking TDM valve (F Valve Open, R Valve Off) (RSG5V** model).

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the OF r error code actually means

The OF r display means your refrigerator has been put into a special test mode where the fresh food section is temporarily turned off so a technician can check a valve that controls cooling. The freezer side is still running, but the fridge section will not cool while this mode is active. If you did not intentionally activate this mode, it likely means a button combination was accidentally pressed and the mode should be exited as soon as possible.

Diagnostic procedure

The full OF r procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
Confirm the fault
Power cycle the unit: switch off the breaker for 60 seconds, then restore power. If the code returns, the fault is persistent and the procedure below isolates the cause.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock OF r procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of OF r

Ranked by how often they cause this code
  1. 1Accidental activation via control panel
  2. 2Intentional technician diagnostic test
  3. 3Stuck or malfunctioning control panel button
  4. 4Control board anomaly

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about OF r

What does OF r mean on a LG refrigerator?
OF r stands for Fridge-Off Forced Operation on LG RSG5V series refrigerators. In this mode, the compressor runs at 3600 RPM while the fresh food compartment cooling is suspended and the TDM valve is held in a fixed position with the fridge valve open and the freezer valve off. This is a diagnostic test state used to evaluate TDM valve behavior, not a standard fault code. The fridge section will not cool normally while this display is active.
Is it safe to leave my LG refrigerator in OF r mode?
It is not safe to leave the refrigerator in OF r mode for extended periods if food is stored in the fresh food compartment. Because the fridge section is deliberately shut off during this mode, temperatures in that compartment will rise over time, creating a food safety risk. The freezer compartment may continue operating depending on system behavior, but the fresh food section should be considered unprotected. Exit the mode as soon as possible and verify that temperatures return to normal operating ranges.
How much does it cost to repair an LG refrigerator showing OF r?
If OF r was triggered accidentally, there is no repair cost since simply exiting the mode restores normal operation. If a stuck panel button is the cause, button or control panel replacement typically costs in the range of $75 to $200 including parts and labor. A failed control board, which is a less common cause, can cost between $200 and $450 or more depending on parts availability and local labor rates. Having a technician confirm the root cause before ordering parts is recommended to avoid unnecessary expense.
How do I exit OF r mode on my LG refrigerator?
To exit OF r mode, use the same control panel button sequence that is used to navigate LG's forced operation or diagnostic menu. On most LG models, pressing and holding the relevant buttons for several seconds will cycle through or exit the diagnostic modes. Consult the specific button layout for your RSG5V model, as the exact sequence can vary by production run. If the mode cannot be exited through button input, a power cycle by unplugging the unit for 60 seconds may reset the control board to normal operation.
Will resetting my LG refrigerator clear the OF r display?
A power reset, achieved by unplugging the refrigerator for approximately 60 seconds and then restoring power, will often clear the OF r forced operation state and return the unit to normal cooling mode. However, if a stuck control panel button or a control board issue is causing the mode to activate repeatedly, the display may return after reset. In those cases, inspecting the panel buttons for physical damage and evaluating the control board would be the next steps.