LG Refrigerator Error Code UU/UU
Over-cooling and weak-cooling in upper and lower part at the same time; insufficient cooling in upper and…
Over-cooling and weak-cooling in upper and lower part at the same time; insufficient cooling in upper and lower part; operation malfunction and OLP activated.
First step from the service manual
Check switch valve terminal location; check for capillary tube welding clog; check for improper coolant valve operation.
The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.
Get the full diagnostic procedure for UU/UU.
- Step-by-step tests with expected resistance, voltage, and continuity values
- Wiring diagram references and connector pinouts from the OEM service manual
- Verified part numbers when replacement is required
$29/month · Cancel anytime · Or $9.95 3-day pass
What UU/UU means on a LG refrigerator
The UU/UU error code on an LG refrigerator signals a simultaneous cooling failure in both the upper and lower compartments. Unlike single-zone faults, this code indicates the entire refrigeration circuit is compromised, producing a condition where both sections are experiencing either over-cooling or insufficient cooling at the same time. This dual-zone failure pattern points toward a central component in the sealed system or control circuit rather than an isolated evaporator or sensor issue. The overload protector (OLP) activation noted in this fault confirms the compressor or a related electrical component has tripped a safety device, cutting operation before damage can occur.
The switch valve, often a dual-function solenoid valve used in LG's linear or dual-evaporator systems, controls refrigerant flow direction between the fresh food and freezer circuits. If this valve fails to shift position correctly, refrigerant distribution becomes unbalanced across both zones simultaneously. A welding clog in the capillary tube is another high-probability cause: capillary tubes meter refrigerant flow, and any blockage from contamination or a manufacturing defect in a brazed joint will restrict or stop refrigerant movement entirely, starving both compartments. Improper coolant valve operation, whether from an electrical fault, a failed coil, or a stuck mechanical spool, produces the same full-system symptom pattern.
Diagnostic work should begin at the switch valve terminals, confirming correct voltage is being delivered and that the valve coil resistance is within specification. From there, a pressure test or temperature monitoring across the capillary tube inlet and outlet can reveal a restriction. If the OLP has tripped, identifying why the compressor overloaded, whether from refrigerant overcharge, a locked rotor, or high discharge pressure caused by a blockage, is essential before resetting or replacing any components.
Source: manufacturer service documentation.
Common causes of UU/UU
- 01
Improper switch valve operation
Part replacementThe switch valve controls refrigerant distribution between both compartments. If the valve coil fails, the spool sticks, or terminal connections are loose, refrigerant flow to both zones is disrupted simultaneously.
- 02
Capillary tube welding clog
Part replacementA blockage at or near the brazed joint of a capillary tube restricts refrigerant flow through the entire circuit. This can result from contamination, moisture, or a defective weld introduced during manufacturing or a prior repair.
- 03
OLP (overload protector) activation
Wiring / connectionThe overload protector trips when the compressor draws excessive current, shutting down the sealed system. This is a symptom of an underlying issue such as a refrigerant restriction, locked rotor, or excessive discharge pressure rather than a standalone failure.
- 04
Refrigerant restriction or loss
Part replacementLow refrigerant charge or a blockage in the sealed system reduces cooling capacity across both zones at the same time. Pressure testing the system is required to confirm this condition.
- 05
Switch valve terminal connection fault
Wiring / connectionLoose, corroded, or improperly seated terminals at the switch valve can prevent the valve from receiving the correct signal to operate, mimicking a failed valve without requiring part replacement if connections are restored.
Frequently asked questions about UU/UU
What does UU/UU mean on a LG refrigerator?
Can I fix a UU/UU error on my LG refrigerator myself?
Is a UU/UU error on an LG refrigerator a safety concern?
Will resetting my LG refrigerator clear the UU/UU error?
How much does it cost to repair a UU/UU error on an LG refrigerator?
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass