Sub-Zero Refrigerator Error Code 87

Speed information from electronic control board is out of specification (700TF/I-2V only).

Speed information from electronic control board is out of specification (700TF/I-2V only).

First step from the service manual

If not experiencing cooling problems, clear error code. If cooling problems, check serial communication wire leads between control board and VS compressor controller; if good, replace both.

The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.

MyPros+ Max

Get the full diagnostic procedure for 87.

  • Step-by-step tests with expected resistance, voltage, and continuity values
  • Wiring diagram references and connector pinouts from the OEM service manual
  • Verified part numbers when replacement is required
Get the full procedure

$29/month · Cancel anytime · Or $9.95 3-day pass

What 87 means on a Sub-Zero refrigerator

Error code 87 on a Sub-Zero refrigerator indicates that the speed information being communicated from the electronic control board is outside the acceptable operating specification. This code is specific to the 700TF/I-2V model and involves the variable-speed (VS) compressor system. The control board continuously sends speed commands and receives feedback data through a serial communication link to the VS compressor controller. When this data falls outside the expected range or becomes corrupted, the unit logs error code 87 to flag the discrepancy.

The most common root cause is a fault in the serial communication wire leads that run between the main electronic control board and the VS compressor controller. These wires can develop intermittent breaks, loose connections, or corrosion over time, all of which disrupt the data signal. If the wiring and connections are intact and the problem persists, the fault is likely internal to either the control board itself or the VS compressor controller, requiring replacement of both components together.

Importantly, this error does not always correlate with a cooling failure. If the refrigerator is maintaining proper temperatures and no cooling problems are present, the error may be transient and can be cleared without further action. However, if cooling performance is compromised alongside this code, systematic diagnosis of the communication circuit and its components is necessary to restore proper compressor speed regulation.

Source: manufacturer service documentation.

Common causes of 87

  1. 01

    Faulty serial communication wiring

    Wiring / connection

    The wire leads connecting the electronic control board to the VS compressor controller may have a break, loose terminal, or corroded connection that disrupts the speed data signal. Visually inspecting and testing the continuity of these leads is the first physical diagnostic step.

  2. 02

    Loose or disconnected wiring connector

    Wiring / connection

    Connectors at either end of the serial communication circuit can loosen over time due to vibration. Reseating the connectors at both the control board and the VS compressor controller may resolve the fault.

  3. 03

    Faulty VS compressor controller

    Part replacement

    If wiring checks out, the VS compressor controller itself may be sending or interpreting speed data incorrectly. This component is replaced as a pair with the main control board when the communication circuit is confirmed to be intact.

  4. 04

    Faulty electronic control board

    Part replacement

    The main electronic control board may be generating out-of-specification speed commands, causing the error. Because the two boards work in tandem, both the control board and VS compressor controller are replaced together rather than individually.

  5. 05

    Transient or intermittent signal error

    Wiring / connection

    In some cases, a temporary electrical disturbance or software glitch can cause a one-time out-of-spec speed reading. If no cooling problems are present, clearing the code and monitoring the unit is the appropriate first response.

See the test procedure for each cause

Frequently asked questions about 87

What does 87 mean on a Sub-Zero refrigerator?
Error code 87 indicates that speed information from the electronic control board is outside the acceptable specification for the VS compressor system. This code applies specifically to the 700TF/I-2V model. It points to a communication issue between the main control board and the VS compressor controller, which may or may not be accompanied by actual cooling problems.
Can I reset error code 87 myself and will it clear the fault?
If your Sub-Zero is cooling normally and you have no other symptoms, clearing the error code is the recommended first step and may resolve the issue entirely. However, if the underlying communication problem between the control board and VS compressor controller is still present, the code will likely return. Clearing the code without addressing a wiring or component fault only provides a temporary result.
Is error code 87 a safety concern?
Error code 87 does not indicate a safety hazard such as a fire or electrical danger. The primary concern is whether your refrigerator is maintaining safe food storage temperatures. If cooling is unaffected, the risk is low. If temperatures are rising inside the unit, food safety becomes a concern and service should be scheduled promptly.
How much does it cost to fix error code 87 on a Sub-Zero refrigerator?
Repair costs vary depending on the root cause. If the issue is a loose connector or damaged wire, the cost is generally limited to a service call fee, typically in the range of $100 to $200. If both the electronic control board and VS compressor controller need replacement, parts and labor combined can range from $600 to $1,500 or more, depending on parts availability and local labor rates.
Do I need to replace both the control board and the VS compressor controller?
Only if the serial communication wiring between the two components has been inspected and confirmed to be in good condition. If the wiring checks out and the fault persists, the diagnostic procedure calls for replacing both the electronic control board and the VS compressor controller together. Replacing just one without the other is not recommended in this situation, as the components are designed to work as a matched pair in the communication circuit.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass