mypros+
Model reference

Sub Zero 700-2

Refrigerator

5 documents24 error codes19 service modes

Available documentation

Service Manual

  • Technical Service Manual Integrated (700-2) Series182 pg
    Covers this model
  • Integrated (700-2) Series Technical Service Manual6 pg
    Covers this model
  • 700 Service Manual166 pg
    Covers this model

Training

  • Technical Service/Training Manual228 pg
    Covers this model

Quick Reference

  • Condensed Electronic Control Information Booklet126 pg
    Covers this model
MyPros+ Max

Diagnose your Sub Zero 700-2.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (24)

CodeMeaning
05Refrigerator cabinet thermistor read open or shorted for 10+ seconds, or…06Refrigerator evaporator thermistor read open or shorted for 10+ seconds, or…07Freezer cabinet thermistor read open or shorted for 10+ seconds, or repeatedly…08Freezer evaporator thermistor read open or shorted for 10+ seconds, or…20Defrost under-heat with no voltage feedback through Gray/White wire at defrost…21Defrost overheat condition detected.22No voltage feedback through Gray/White wire at defrost start.23Defrost overheat with no voltage feedback through Gray/White wire at defrost…24Defrost under-heat condition detected.80High variable speed compressor differential pressure or low voltage supplied to…81High amperage draw at variable speed compressor (700TF/I-2V only).82VS compressor could not maintain lowest minimum speed at highest current draw…83Locked variable speed compressor rotor (700TF/I-2V only).84Short circuit at VS compressor controller output circuit (700TF/I-2V only).85VS compressor converter overheated and shut down VS compressor (700TF/I-2V…86Serial communication failure between VS compressor controller and electronic…87Speed information from electronic control board is out of specification…88Electronic control board not receiving status data in response to speed…E0Communication error between control board and control panel (base units only).E3Communication error between control board and control panel (base units only).ECExcessive compressor run with error codes registered in the electronic control…EECompartment or evaporator thermistor (or its wiring) is open, shorted, or has a…ICEFlashing ICE and SERVICE annunciators indicate icemaker water valve solenoid…SERVICEFlashing SERVICE annunciator alone indicates excessive compressor run (tall…

Service modes (19)

  • diagnosticUnit must be ON
  • Diagnostic Mode (Base Units)With the unit ON, press and hold either COLDER key, then press the UNIT ON/OFF key, then release…
  • Diagnostic Mode (Tall Units)With the unit ON, press and hold either COLDER key, then press the UNIT ON/OFF key, then release…
  • Manual Compartment Disable Mode (Tall Units Only)Switch unit OFF using UNIT ON/OFF key
  • Manual Component Activation Mode (Tall Units)With the unit ON, press and hold the desired compartment COLDER key and the UNIT ON/OFF key for 10…
  • Manual Freezer Evaporator DefrostPress and hold the ICE key at the control panel for 5 seconds, then release.
  • manual_compartment_disableSwitch unit OFF using UNIT ON/OFF key
  • manual_component_activationUnit must be ON
  • manual_freezer_evaporator_defrostPress and hold ICE key at control panel for 5 seconds, then release.
  • Sabbath ModeSwitch unit OFF using UNIT ON/OFF key
  • sabbath_modeSwitch unit OFF using UNIT ON/OFF key
  • Showroom ModeSwitch unit OFF using UNIT ON/OFF key
  • showroom_modeSwitch unit OFF using UNIT ON/OFF key
  • Temperature Log Recall Mode (Tall Units - Compartment and Evaporator)With the unit ON and in Diagnostic Mode, toggle to desired thermistor temperature
  • Temperature Log Recall Mode (Tall Units - Compartment Only)With the unit ON, press and hold the desired compartment WARMER key, then press the UNIT ON/OFF…
  • Temperature Units Selection ModeWithin the first minute after switching the unit ON, press and hold the door ajar alarm bell key…
  • temperature_log_recall_compartment_and_evaporatorUnit must be ON and in Diagnostic Mode
  • temperature_log_recall_compartment_onlyUnit must be ON
  • temperature_units_selectionMust be performed within first minute after switching unit ON

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass