Trane Furnace Error Code 6

1st stage pressure switch has opened 5 times within one cycle

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the 6 error code actually means

Your furnace tried to start five times in a row and failed each time because a safety sensor detecting proper airflow kept shutting things down. As a result, the furnace has locked itself out for one hour to protect itself. After the hour passes, it will try again, but the underlying problem needs to be fixed or it will lock out again.

Diagnostic procedure

The full 6 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Follow same troubleshooting as 3 flash fault (1st stage pressure switch fault); verify wiring, inducer motor operation, and pressure readings.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 6 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 6

Ranked by how often they cause this code
  1. 1Blocked or restricted condensate drain
  2. 2Cracked, kinked, or disconnected pressure switch hose
  3. 3Weak or failing inducer motor
  4. 4Faulty 1st stage pressure switch
  5. 5Blocked or restricted vent piping

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 6

What does 6 mean on a Trane furnace?
A code 6 on a Trane furnace means the 1st stage pressure switch opened five times within one operating cycle, which caused the control board to initiate a one-hour lockout. The pressure switch monitors draft airflow created by the inducer motor, and repeated dropout indicates a persistent problem with draft pressure, the switch itself, or connected components. The furnace will attempt to restart automatically after 60 minutes, but the fault will recur unless the underlying cause is corrected.
Is it safe to run my furnace when a code 6 is active?
The one-hour lockout is a built-in safety feature, and the furnace will not fire while the lockout is active. The fault itself relates to draft pressure and airflow monitoring, which are part of the furnace's combustion safety system. It is best not to attempt bypassing the lockout, and the cause should be diagnosed before the furnace is returned to normal operation.
What is the difference between a 3-flash and a 6-flash fault on a Trane furnace?
A 3-flash fault indicates that the 1st stage pressure switch has opened during a single ignition attempt, which may be caused by a transient issue or a developing problem. A code 6 fault means the same pressure switch failure occurred five times within one cycle, signaling a more persistent issue that has now triggered a protective one-hour lockout. Both faults point to the same components and use the same diagnostic approach, but a code 6 indicates the problem is consistent enough that the control board has determined a cooldown period is necessary.
Can I reset my Trane furnace to clear a code 6 lockout?
The furnace will automatically exit the one-hour lockout and attempt to restart on its own, so a manual reset is not required. However, resetting the furnace early by cycling the power will not fix the root cause. If the problem with the pressure switch circuit is not resolved, the furnace will repeat the same fault sequence and lock out again.
How much does it cost to repair a Trane furnace with a code 6 fault?
Repair costs vary depending on the cause. Simple fixes like clearing a blocked condensate drain or replacing a cracked pressure switch hose typically cost between $75 and $200 for a service call. A faulty pressure switch replacement generally runs between $100 and $300 including parts and labor. Inducer motor replacement is more expensive, typically ranging from $300 to $700 or more depending on the model.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass