Trane Furnace Error Code ERR 119

Temperature sensor failure-temperature sensor 1 or 2 shorted or open.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the ERR 119 error code actually means

Your Trane furnace has detected a problem with one of its temperature sensors, which are small devices that measure heat inside the unit to keep it running safely. The sensor is either broken or has a wiring fault, so the furnace cannot accurately read its internal temperature. Until the sensor issue is resolved, the furnace may not run or will shut down to avoid unsafe conditions.

Diagnostic procedure

The full ERR 119 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
Confirm the fault
Power cycle the unit: switch off the breaker for 60 seconds, then restore power. If the code returns, the fault is persistent and the procedure below isolates the cause.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock ERR 119 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of ERR 119

Ranked by how often they cause this code
  1. 1Failed thermistor element
  2. 2Damaged or broken sensor wiring
  3. 3Corroded or loose sensor connector
  4. 4Heat-damaged wire insulation
  5. 5Control board input circuit fault

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about ERR 119

What does ERR 119 mean on a Trane furnace?
ERR 119 indicates that temperature sensor 1 or temperature sensor 2 has been detected as either shorted (near-zero resistance) or open circuit (very high or infinite resistance). These sensors monitor thermal conditions inside the furnace to ensure safe burner and blower operation. When the control board cannot get a valid reading from a sensor, it triggers ERR 119 and typically halts the heating cycle. The fault points to a failed sensor, damaged wiring, or a faulty connector.
Is it safe to run my furnace with ERR 119 active?
Operating the furnace with a temperature sensor fault is not recommended. The sensor exists to give the control board accurate thermal data so it can prevent overheating and unsafe heat exchanger conditions. Without reliable sensor input, the furnace cannot properly protect itself or your home. Most Trane furnaces will lock out heating operation when ERR 119 is active, so the unit may not run at all until the fault is resolved.
How much does it cost to repair ERR 119 on a Trane furnace?
Repair costs vary depending on what is causing the fault. A simple connector cleaning or re-seating may cost only a service call fee, typically in the range of $75 to $150. Replacing a temperature sensor usually adds parts costs of roughly $20 to $80 depending on the specific sensor required. If the control board is at fault, board replacement can run between $200 and $600 or more for parts alone, plus labor.
Can I fix ERR 119 on my Trane furnace myself?
A knowledgeable DIYer can inspect wiring and connectors for visible damage, corrosion, or loose connections and address those issues. Testing the thermistor with a multimeter to check for an open or short is also within reach if you have basic electrical troubleshooting skills. However, replacing a temperature sensor or control board involves working inside the furnace cabinet and requires comfort with electrical components, so many homeowners prefer to call a qualified technician for this repair.
Will resetting the furnace clear ERR 119?
A reset may temporarily clear the error code, but if the underlying sensor, wiring, or connector fault still exists, ERR 119 will return once the furnace attempts to operate and checks the sensor again. Resetting without diagnosing the root cause is not a lasting solution. The fault needs to be traced to the specific sensor or wiring issue and repaired before the error will stay cleared.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass