Trane Furnace Error Code ERR 93

Gas valve fault-control senses 24V present at gas valve when it should not be, or control tried to turn on gas valve but 24V not sensed.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the ERR 93 error code actually means

Your furnace's control board detected a problem with the gas valve, either catching it with power when it should be off, or not seeing power when it tried to open. This is a safety lockout that stops the furnace from running until the issue is resolved. A technician will need to inspect the gas valve, its wiring, and the control board to find the exact cause.

Diagnostic procedure

The full ERR 93 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
Confirm the fault
Power cycle the unit: switch off the breaker for 60 seconds, then restore power. If the code returns, the fault is persistent and the procedure below isolates the cause.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock ERR 93 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of ERR 93

Ranked by how often they cause this code
  1. 1Faulty gas valve solenoid
  2. 2Defective control board gas valve relay
  3. 3Damaged or loose wiring harness
  4. 4Corroded or loose gas valve connector
  5. 5Low or lost 24V transformer output

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about ERR 93

What does ERR 93 mean on a Trane furnace?
ERR 93 is a gas valve fault code indicating the control board detected a 24V discrepancy at the gas valve circuit. This means the board either found voltage present at the gas valve when the valve should have been off, or it commanded the valve open and did not sense the expected 24V. The furnace locks out as a safety precaution until the fault is diagnosed and corrected.
Is ERR 93 on a Trane furnace dangerous?
The error code itself represents a safety lockout that prevents the furnace from operating in an unsafe condition. If the fault is caused by the gas valve receiving unintended power, there is a risk of uncontrolled gas delivery, which makes prompt inspection important. Do not attempt to force the furnace to run while this fault is active. Contact a qualified technician to diagnose the root cause before restoring operation.
How much does it cost to repair ERR 93 on a Trane furnace?
Repair costs vary depending on the root cause. A wiring repair or connector cleaning may run between $75 and $200 in labor. Replacing the gas valve typically costs between $200 and $500 including parts and labor. A control board replacement can range from $300 to $700 or more depending on the specific board. A diagnostic service call from a licensed HVAC technician will identify the exact failed component before parts are ordered.
Can I fix ERR 93 on my Trane furnace myself?
Some basic checks, such as inspecting the gas valve wiring connector for corrosion or loose pins, can be done by a knowledgeable DIYer. However, any work involving the gas valve itself or the control board relay should be performed by a licensed HVAC technician, since improper repairs to gas valve circuits carry serious safety risks. Do not attempt to bypass or defeat any part of the gas valve control circuit.
Will resetting the furnace clear ERR 93?
A power reset may temporarily clear the fault code and allow the furnace to attempt another ignition cycle, but if the underlying electrical or component problem remains, the fault will return. Repeatedly resetting the furnace without addressing the cause can mask the issue and delay a proper repair. A persistent ERR 93 after multiple resets indicates a hardware failure that requires hands-on diagnosis.