U-Line Ice Maker Error Code R Temp Hi 6H+
Right zone temperature is +10° over set point for over 6 hours.
Right zone temperature is +10° over set point for over 6 hours.
First step from the service manual
If excessive frost is noted, inspect door and door gasket for proper seal and alignment.
The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.
Get the full diagnostic procedure for R Temp Hi 6H+.
- Step-by-step tests with expected resistance, voltage, and continuity values
- Wiring diagram references and connector pinouts from the OEM service manual
- Verified part numbers when replacement is required
$29/month · Cancel anytime · Or $9.95 3-day pass
What R Temp Hi 6H+ means on a U-Line ice maker
The R Temp Hi 6H+ error code on a U-Line ice maker indicates that the right zone temperature has climbed to more than 10 degrees Fahrenheit above the programmed set point and has remained there for over six consecutive hours. This is a sustained thermal fault, meaning the unit has failed to maintain its target temperature for an extended period rather than experiencing a brief spike. The right zone typically refers to the refrigerated or ice storage compartment, depending on the model configuration, and the 6-hour threshold is built in to distinguish a genuine cooling failure from a temporary recovery after door openings or heavy loading.
The most common entry point for this diagnostic is checking for excessive frost accumulation, which can indicate warm, humid air is entering the cabinet. A compromised door gasket or a door that is misaligned will allow ambient air infiltration, raising interior temperatures and causing the refrigeration system to work beyond its capacity. Over time, frost buildup on evaporator surfaces insulates the coil, reducing heat transfer efficiency and compounding the temperature rise.
Beyond door seal issues, the fault can stem from refrigeration system problems including a low refrigerant charge, a failing condenser fan motor, dirty condenser coils restricting airflow, or a defective evaporator fan. A malfunctioning thermistor in the right zone could also report falsely elevated temperatures, triggering the code even when actual cabinet conditions are acceptable. Systematic diagnosis should move from the simplest mechanical checks to refrigerant circuit evaluation.
Source: manufacturer service documentation.
Common causes of R Temp Hi 6H+
- 01
Faulty or misaligned door gasket
Part replacementA worn, torn, or poorly seated door gasket allows warm ambient air into the cabinet, raising the right zone temperature continuously. Inspect the gasket for visible gaps, tears, or areas that do not make firm contact with the cabinet frame.
- 02
Door misalignment
Wiring / connectionIf the door is not hanging level or is obstructed from closing fully, the seal will be inconsistent even with an intact gasket. Check hinge hardware and ensure nothing is blocking the door from closing completely.
- 03
Frost-blocked evaporator
Wiring / connectionExcessive frost accumulation on the evaporator coil insulates it and prevents proper heat exchange, reducing cooling capacity in the right zone. Look for unusually heavy frost buildup inside the cabinet as a sign of this issue.
- 04
Dirty or obstructed condenser coils
Wiring / connectionDust and debris on the condenser coils reduce the unit's ability to reject heat, causing the compressor to work harder and the cabinet temperature to rise over time. Clean the condenser coils and verify adequate clearance around the unit for ventilation.
- 05
Defective right zone thermistor
Part replacementA failing temperature sensor in the right zone may report inaccurate readings that are higher than actual conditions, triggering the error code without a true cooling failure. This requires testing the thermistor's resistance values against the expected specification for the model.
Frequently asked questions about R Temp Hi 6H+
What does R Temp Hi 6H+ mean on a U-Line ice_maker?
How do I fix the R Temp Hi 6H+ error on my U-Line ice maker?
Will resetting the unit clear the R Temp Hi 6H+ error?
Is the R Temp Hi 6H+ error on a U-Line ice maker a safety concern?
How much does it cost to repair a U-Line ice maker showing R Temp Hi 6H+?