Model reference
U-Line U-2175RCGOL-00
Ice Maker
3 documents30 error codes5 service modes
Available documentation
Service Manual
- Service and Parts Manual38 pg
- Service and Parts Manual40 pg
- Service Manual Modular 3000 Series44 pg
MyPros+ Max
Diagnose your U-Line U-2175RCGOL-00.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (30)
CodeMeaning
Amb Thrm OpenAmbient thermistor circuit is open.Amb Thrm ShortAmbient thermistor circuit is shorted.Door Open 5MDoor switch has been open for more than 5 minutes.Evap T OpenEvaporator thermistor circuit is open.Evap T ShortEvaporator thermistor circuit is shorted.L Door Open 5MLeft door switch has been open for more than 5 minutes.L Evap T OpenLeft evaporator thermistor circuit is open.L Evap T ShortLeft evaporator thermistor circuit is shorted.L Temp Hi 12H+Left zone temperature is +10° over set point for over 12 hours.L Temp Hi 6H+Left zone temperature is +10° over set point for over 6 hours.L Temp Lo 12H+Left zone temperature is -10° under set point for over 12 hours.L Temp Lo 6H+Left zone temperature is -10° under set point for over 6 hours.L Zone T OpenLeft zone thermistor circuit is open.L Zone T ShortLeft zone thermistor circuit is shorted.No CommUnit lost communication between the main control board and the display.R Door Open 5MRight door switch has been open for more than 5 minutes.R Evap T OpenRight evaporator thermistor circuit is open.R Evap T ShortRight evaporator thermistor circuit is shorted.R Temp Hi 12H+Right zone temperature is +10° over set point for over 12 hours.R Temp Hi 6H+Right zone temperature is +10° over set point for over 6 hours.R Temp Lo 12H+Right zone temperature is -10° under set point for over 12 hours.R Temp Lo 6H+Right zone temperature is -10° under set point for over 6 hours.R Zone T OpenRight zone thermistor circuit is open.R Zone T ShortRight zone thermistor circuit is shorted.Temp Hi 12H+Zone temperature is more than 10°F over set point for over 12 hours.Temp Hi 6H+Zone temperature is more than 10°F over set point for over 6 hours.Temp Lo 12H+Zone temperature is more than 10°F under set point for over 12 hours.Temp Lo 6H+Zone temperature is more than 10°F under set point for over 6 hours.Zone T OpenZone thermistor circuit is open.Zone T ShortZone thermistor circuit is shorted.Service modes (5)
- Customer MenuHold Select button for 5 seconds.
- Relay ToggleEnter Service Menu, scroll to 'Relay Toggle' using Down, press Select.
- Self TestEnter Service Menu, then scroll to 'Self Test' using Down, press Select.
- Service MenuHold both Up and Zone Toggle buttons simultaneously for 5 seconds.
- Showroom ModeEnter Service Menu, scroll to 'Showroom Mode', press Select, select 'Off', press Select, toggle to…
Full entry steps, exit procedures, and test sequences are available in Max.