Whirlpool Hood Error Code F8E5

Exhaust air temperature detection failure (HF NTC thermistor).

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the F8E5 error code actually means

Your range hood has detected a problem with the temperature sensor that monitors the air being exhausted through the hood. This sensor, called a thermistor, sends continuous readings to the control board, and the board is reporting that the readings have stopped or are outside the normal range. This typically means the sensor has failed, a wire has come loose, or the sensor is no longer reading temperatures accurately.

Diagnostic procedure

The full F8E5 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Enter Diagnostics mode (CANCEL-CANCEL-START), press WARM HOLD to display HF NTC thermistor reading and verify temperature reading is at room temperature (typically 50°F to 90°F).
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock F8E5 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of F8E5

Ranked by how often they cause this code
  1. 1Failed HF NTC thermistor
  2. 2Damaged or disconnected wiring harness to the HF NTC thermistor
  3. 3Corroded or loose thermistor connector terminals
  4. 4Faulty control board

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about F8E5

What does F8E5 mean on a Whirlpool hood?
F8E5 means the control board has detected a failure in the exhaust air temperature sensing circuit, specifically the HF NTC thermistor. This thermistor monitors air temperature inside the exhaust path, and the code triggers when its signal falls outside the range the board expects. The fault can originate from the thermistor itself, the wiring connecting it, or in rarer cases, the control board.
Is it safe to use my Whirlpool hood while F8E5 is active?
Using the hood with an active F8E5 code is not recommended. The thermistor monitors exhaust air temperature, and without a reliable reading, the hood cannot properly manage heat levels during operation. Running the appliance in this state could allow temperatures to go unmonitored. Address the fault before resuming regular use.
How do I check the HF NTC thermistor reading on a Whirlpool hood?
Press CANCEL-CANCEL-START to enter diagnostics mode, then press WARM HOLD to display the HF NTC thermistor reading on the control panel. With the hood at room temperature, the value should fall between approximately 50°F and 90°F. A reading outside this range, or no reading at all, confirms the thermistor circuit has a problem that needs further investigation starting at the thermistor and its wiring.
How do I fix F8E5 on a Whirlpool hood?
Start by entering diagnostics mode using the CANCEL-CANCEL-START button sequence, then press WARM HOLD to read the live HF NTC thermistor value. If the reading is within room temperature range (50°F to 90°F), inspect the wiring harness and connector terminals for damage or corrosion. If the reading is absent or wildly out of range, replace the HF NTC thermistor. If both the thermistor and wiring check out, the control board is the next component to test or replace.
How much does it cost to fix a Whirlpool hood F8E5 error?
If only the HF NTC thermistor needs replacement, parts typically cost between $20 and $60 depending on your hood model, and the repair is accessible enough for a DIY technician comfortable with basic disassembly and connector work. If the wiring harness needs repair or replacement, add minimal parts cost but more labor time. A control board replacement is the most expensive scenario, with parts ranging from $100 to $250 or more, and professional installation would add labor charges on top of that.