Wolf Oven Error Code E29
Climate temperature measured 3 times with differential less than 41°F/5°C during 180-second monitoring cycle (active only during first 20 minutes and with climate temp over 194°F/90°C), indicating cooking space not sealed, too much cold food, dirty probe socket, or faulty hot air fan seal.
SourceWolf CSO24 & CSO30-2 (9001333): Serials 13508347 to 13543125: Service Manualp. 5-4
The full E29 procedure
Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.
SourceWolf CSO24 & CSO30-2 (9001333): Serials 13508347 to 13543125: Service Manualp. 5-4
Or subscribe: $29/month for all codes plus Max diagnostics, with 70 Max messages a day. Plus applicable tax.
75,000+ service documents · 20,000+ error codes · 100+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax