Service Manual
- Instruction Sheet - 8530143 - Rev C16 pg
- Instruction Sheet - 854371916 pg
Tech Tip
- Instruction Sheet - 852220612 pg
MyPros+ Max
Diagnose your Admiral 1171AF-36K.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (16)
Service modes (25)
- Agitation and Recirculation Test["Ensure control is off.","Press the prescribed sequence
- ATC Wash Fill Test (Test 2)["Set the Water Temperature Switch to ATC-controlled Warm/Cold","Set the Timer in the Wash cycle…
- Automatic Service Diagnostic Test["Ensure control is off.","Press the prescribed sequence
- Automatic Service DiagnosticsWith control in OFF state, press PREWASH OPTIONS, WASH TIME, PREWASH OPTIONS, WASH TIME within 5…
- Console Keypad and LED TestControl must be in Off state. Perform Key Dance within 5 seconds
- Console Switches and Indicator TestPress WASH/RINSE > ACCUWASH > WASH/RINSE > ACCUWASH within 5 seconds, then press the START pad
- Console Switches and Indicators Test (Keypad and LED Test)["Ensure control is in OFF state.","Key Dance
- Console Switches and Indicators Test (Touch Button and LED Test)["Ensure control is off.","Press the prescribed sequence
- Keypad and LED TestWith control in OFF state, press SOAK, CYCLE SIGNAL, SOAK, CYCLE SIGNAL within 5 seconds. Then…
- Manual DiagnosticsControl must be in Off state. Perform Key Dance within 5 seconds
- Neutral Drain/Spin TestEnter diagnostic mode, then press PERMANENT PRESS keypad
- Neutral Drain/Spin Test (T4)Enter diagnostic mode, then press PERMANENT PRESS. Display shows T4. Cycles through
- Non-ATC Wash Fill Test (Test 1)["Set the Timer for the Wash cycle","Start the washer and the tub will begin filling with…
- Nutate and Recirculate TestWith control in OFF state, press SOAK, CYCLE SIGNAL, SOAK, CYCLE SIGNAL within 5 seconds. Then…
- Pressure Transducer/Agitate TestEnter diagnostic mode, then press NORMAL keypad
- Pressure Transducer/Agitate Test (T3)Enter diagnostic mode, then press NORMAL. Display shows ER while filling to low water level, then…
- Recirculation Pressure Switch TestEnter diagnostic mode, then press WHITEST WHITES keypad
- Recirculation Pressure Switch Test (T2)Enter diagnostic mode, then press WHITEST WHITES
- Service Diagnostic TestsWith control in OFF state, press WASH/RINSE > ACCUWASH > WASH/RINSE > ACCUWASH within 5 seconds
- Spin and Drain TestWith control in OFF state, press SOAK, CYCLE SIGNAL, SOAK, CYCLE SIGNAL within 5 seconds
- Water Inlet and Dispenser Valve Operating Pressure Switch TestWith control in OFF state, press SOAK, CYCLE SIGNAL, SOAK, CYCLE SIGNAL within 5 seconds
- Water Inlet and Dispenser Valve Operating PS TestControl must be in Off state. Perform Key Dance within 5 seconds
- Water Inlet and Dispenser Valve TestEnter diagnostic mode (WASH/RINSE > ACCUWASH > WASH/RINSE > ACCUWASH), then press HEAVY DUTY keypad
- Water Inlet and Dispenser Valve Test (T1)Enter diagnostic mode (WASH/RINSE > ACCUWASH > WASH/RINSE > ACCUWASH), then press HEAVY DUTY…
- Water Inlet Valve and Distributor Operative Pressure Test["Ensure control is off.","Press the prescribed sequence
Full entry steps, exit procedures, and test sequences are available in Max.