Model reference
Amana 11-5D
Air Conditioner
1 document43 error codes8 service modes
Available documentation
Tech Tip
- Instruction Sheet24 pg
MyPros+ Max
Diagnose your Amana 11-5D.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (43)
CodeMeaning
1-1Control detected K2 pilot relay stuck closed.1-2Damaged or corrupted memory on control board, or incompatible software…10-1Dispenser electrical problem10-3Drying fan error2-1Control detected stuck key(s) in keypad or keypad connection.2-2User interface cannot communicate with main control3-1Open connector or component in temperature sensing circuit (open or faulty…3-2Shorted connection or component in temperature sensing circuit, shorted or…3-3OWI calibration failure due to OWI sensor failure or drain hose check valve not…4-3Wash motor not running due to loose connection in motor circuit, faulty wash…5-1Door stuck open5-2Door stuck closed6-1Low or no water6-2Fill valve electrical problem6-3Suds or air in pump causing repeated wash periods.6-4Float switch open6-7Disconnected or damaged flowmeter.6-8Regen valve electrical problem7-1No heat7-2Heater stuck on8-2Drain motor electrical problem8-3Drain motor stuck on9-1Diverter can't find position9-2Diverter stuck on9-3Diverter disk in sump is missing.9-4Lower spray arm errorF1E1Indicates a Cycle Control Unit (CCU) problem.F2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatch; only…F2E2User Interface software errorF3E1Exhaust thermistor is open; temperature drops below 18°F (>50k ohms).View all 43 error codes
F3E2Exhaust thermistor has shorted; temperature above 250°F (<500 ohms).F3E3Inlet thermistor is open; temperature drops below 18°F (>245k ohms).F3E4Inlet thermistor is shorted; temperature above 391°F (<20 ohms).F3E5Inlet and exhaust thermistors are open; will occur if P14 connector is not…F3E6Moisture sensor strip is open; only appears in service diagnostic mode.F3E7Moisture sensor strip has shorted; only appears in service diagnostic mode.F4E1No voltage detected at the heater relay; only appears in service diagnostic…F4E3Restricted/low air flow that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at installation.F6E1Communication error from UI to CCU; communication between CCU and UI has not…F6E2Communication error from CCU to UI; communication between CCU and UI has not…L2Low L2 voltage (less than 50V) detected at installation.PFPower failure occurred while the dryer was running.
Service modes (8)
- Customer-Focused Dryness Level Adjustment1
- Install Diagnostics1
- Loads Test Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Within 5 seconds: press…
- Rapid Advance Mode (Customer Cycles)After starting a customer cycle, press HIGH TEMP
- Service Diagnostic Mode1. Ensure dryer is in standby mode (plugged in with all indicators off). 2. Select any three…
- Service Diagnostics CycleWhile in standby, press any 3 keys in the sequence 1-2-3-1-2-3-1-2-3 with no more than 1 second…
- Software Version Display1
- User Interface/Control System Test1. Activate Service Diagnostic Mode. 2. Press and release the 1st button used to activate Service…
Full entry steps, exit procedures, and test sequences are available in Max.