Error codes (44)
CodeMeaning
F0 E0Factory defaultF03One or more keys permanently pressed on the touch control surface.F1Control failure or UL A/D error(s) detected in the control board.F1 E*Control board failure (all F1 sub-codes indicate control fault).F1 E0EEPROM communications error.F1 E1EEPROM checksum error.F1 E2UL A/D error(s).F1 E4Model ID error.F1 E6Latch signal mismatch error.F1-E0EEPROM communications failure.F1-E1EEPROM checksum failure.F1-E2UL A/D error(s).F12Electronic board and touch module communication error.F13Internal CPU checksum errors.F2Shorted/stuck key detected on the control keypad.F2 E0Shorted key.F2 E1Key tail unplugged.F2-E0Shorted key detected.F2-E1Keytail unplugged from electronic oven control.F22Key sensitivity problem.F3Oven sensor opened or oven sensor shorted.F3 E0Oven temperature sensor fault (open or shorted)F3 E1Lower oven temperature sensor fault (MRC II double oven models).F3 E2Warming drawer temperature sensor fault.F3 E3Clean range over temperature.F3 E4Oven sensor openedF3 E5Oven sensor shortedF3 E6Warming drawer sensor open.F3 E7Warming drawer sensor shorted.F3-E0Oven temperature sensor open circuit.View all 44 error codes
F3-E1Oven temperature sensor shorted.F3-E2Bake range over temperature condition.F3-E3Clean range over temperature condition.F36Temperature probe hardware error.F5 E0Door position switch faultF5 E1Door latch switch/system faultF5 E2Door switch fault.F5-E0Door and latch switches do not agree.F5-E1Door lock solenoid not operating or latch switch failure.F5-E2Latch during CLEAN error.F6 E*Control communication failure.F8 E0N/A.F9House miswiredPFPower failure has occurred.
Service modes (10)
- Electronic Control Board Circuit MonitoringNo manual entry required
- Fault Code Diagnosis ModeThe cooktop automatically enters failure mode when a fault is detected
- Last Error Code RecallPress and hold the CANCEL/OFF key for 5 seconds
- LCC Diagnostic Mode (LCC90/LCC95/LCC180)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' key to cycle through diagnostic…
- LCC190 Diagnostic Mode (Self Clean, Convection models)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME or TEMP/HOUR '+' key to cycle through…
- MRC Diagnostic Mode["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' key to cycle through diagnostic…
- MRC Diagnostic Mode (Fan/True Convection Electric - Oven Light entry)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' key to cycle through diagnostic…
- MRC II Diagnostic Mode (Number 3 key entry - KitchenAid models)["Press OFF/OFF/START or CANCEL/CANCEL/START in sequence.","Press the number '3' key to cycle…
- MRC II Diagnostic Mode (TEMP/TIME entry)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' keypad to cycle through diagnostic…
- Oven Temperature CalibrationPress and hold the BAKE keypad for 5 seconds. The current offset will be shown in the 3-digit…