Model reference
Amana CR3-1/P58094-23C
Air Conditioner
60 error codes15 service modes
MyPros+ Max
Diagnose your Amana CR3-1/P58094-23C.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (60)
CodeMeaning
1c1cShorted key detected on the control circuit board keyboard.1c2cKeyboard tail disconnected or keyboard loop has improper value.1c31Cancel key circuit problem (cancel key improper value) on upper/single oven…1c32Cancel key circuit problem (cancel key improper value) on lower oven cavity.1c4cPower micro communication failure (CRC invalid).1c6cEEPROM error1c7cControl not calibrated1c81Cook profile corrupted in EEPROM for upper/single oven cavity (CRC invalid).1c82Cook profile corrupted in EEPROM for lower oven cavity (CRC invalid).1d11Runaway temperature (650°F) detected with door unlocked on upper/single oven…1d12Runaway temperature (650°F) detected with door unlocked on lower oven cavity.1d21Runaway temperature (950°F) detected with door locked on upper/single oven…1d22Runaway temperature (950°F) detected with door locked on lower oven cavity.3d11Temperature sensor failure (open) on upper/single oven cavity3d12Temperature sensor failure (open) on lower oven cavity3d21Temperature sensor failure (short) on upper/single oven cavity3d22Temperature sensor failure (short) on lower oven cavity3d41Meat probe shorted3d51Meat probe not calibrated4d11Door switch position failure4d12Door switch position failure4d21No Reverse Airflow Fan rotation (no/low RPM) on upper/single oven cavity.4d22No Reverse Airflow Fan rotation (no/low RPM) on lower oven cavity.4d31Reverse Airflow Fan state error4d32Reverse Airflow Fan state error4d41High Reverse Airflow Fan rotation (high RPM) on upper/single oven cavity.4d42High Reverse Airflow Fan rotation (high RPM) on lower oven cavity.4d51Door switch circuit failure4d52Door switch circuit failure9d11Door latch will not lock on upper/single oven cavityView all 60 error codes
9d12Door latch will not lock on lower oven cavity9d21Door latch will not unlock on upper/single oven cavity9d22Door latch will not unlock on lower oven cavity9d31Door latch both locked and unlocked simultaneously on upper/single oven9d32Door latch both locked and unlocked simultaneously on lower ovenAXIAL PROBE FAULTProblem with the axial temperature sensor circuit.BURNER CONTROL FAULTGas return valve signal did not turn on before DSI purge time expired or turned…BURNER HIGH-LIMIT FAULTBurner high-limit switch opened during the cycle while the heat was on.BURNER PURGE FAULTGas return signal detected before the heat signal was sent out by the…CHECK CONTROL BOARD FUSE #2Main fuse (fuse 2) on the Phase 7 computer board has opened; controller will…CLEAN LINTLint drawer has not been opened within the programmed Lint Cleaning Frequency…DISCONNECTED WATER VALVES.A.F.EEXHAUST HIGH TEMP FAULTTemperature sensor input shows overheating with steady gradual increase to a…EXHAUST HIGH-LIMIT FAULTTumbler safety over-temperature switch has opened.EXHAUST PROBE FAULTProblem with the exhaust temperature sensor circuit.FLAME FAULTGas valve return signal was lost after the DSI proof time, occurring five…IGNITION FAULTGas valve return signal was lost during the DSI proof time and retry count has…LINT ACCESS OPENLint drawer is open and needs to be closed.MAIN DOOR OPENEDMain door is open when it should be closed.MODEL ERROR, ENTER CORRECT MODELController detected a mismatch between programmed dryer type and actual inputs…OPEN THERMISTOR PROBES.A.F.EROTATION SENSOR FAULTTime between rotational sensor pulses exceeded 10 seconds, indicating tumbler…S.A.F.E. SYSTEM ACTIVATEDPhase 7 controller has detected a fire and is currently extinguishing the flame.S.A.F.E. SYSTEM DISABLEDA fault in the S.A.F.ES.A.F.E. SYSTEM WAS ACTIVATEDPhase 7 controller detected a fire and has extinguished the flame.SAIL SWITCH CLOSED FAULTSail switch is in the closed position prior to starting; switch did not open…SAIL SWITCH OPEN FAULTSail switch did not close within 8 seconds of starting/restarting, or sail…SHORTED THERMISTOR PROBES.A.F.ESHORTED WATER VALVES.A.F.EWATER NOT CONNECTEDNo water pressure at the S.A.F.E
Service modes (15)
- Diagnostic Code Display Mode (H1 Controls)Press and hold AUTOSET pad for 3 seconds at power-up.
- Diagnostic Code Display Mode (H3 Controls)Press and hold Upper Cancel and Timer for 3 to 5 seconds within 5 minutes of power up.
- Diagnostic Code Display Mode (NSC Controls)Press and hold the More + pad for 3 to 5 seconds when powering up the unit (within 60 seconds of…
- Faults Access (EOC III Controls)1
- One-Watt Standby Mode (NSC Controls)Press and hold Cancel and Less
- Quick Test Mode (EOC III Controls)1
- Quick Test Mode (H1 Controls - Convection Model)1
- Quick Test Mode (H1 Controls - Non-Convection Model)1
- Quick Test Mode (H2/H2.5 Controls)1
- Quick Test Mode (H3 Controls)1
- Quick Test Mode (M1/M2 Controls)1
- Quick Test Mode (NSC Non-Self Clean Controls)1
- S.A.F.E. System Diagnostic DisplayWhen the display reads 'S.A.F.E
- Service Mode (EOC III Controls)1
- Test Mode (UH Controls)1
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana air conditioner models
75,000+ service documents · 20,000+ error codes · 100+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax